以前遇到smartplant licsense问题基本上PDS或3D,PID程序因某种原因异常中断引起的,一般客户端·重启或运行一下license回收工具就可以解决。实在不行的,第二天会自动释放license。

昨天碰到的很怪,即使过了一个晚上,license还是挂在那里。回收了及几次都没有成功。看了提示,说是connect refused。刚开始以为是windows 防火墙·引起的,关闭防火墙问题依旧。上网搜了,按照·下面文章的方法才得以解决。

(1)卸载并重装license manager

(2)先用netstat -noa,查看807端口所运行的进程号,到task manager中看pdlice。

http://www.asbuilt-dba.com/Forum/tabid/53/forumid/13/threadid/40/scope/posts/Default.aspx

Please find bellow troubleshooting for PDLicense:

Problem: SPF product tag is invalid

Solution:

When an invalid tag message pops up, the software is trying to move and validate the seats that are taken during the installation of the new key. Possible an older version of lice was installed before and the old key has not been removed before installing the new key. At the dos command enter pdlice -m and get the output to see if there is some weird seat tag there.

Remove key - Uninstall SW and verify registry, rebbot – install latest and generate new machine id and key.

Problem:Server Key file mismatch

Solution:

This problem has been addressed in SPLM 9.0.

This is the explanation and the work around: "The license file and the DSKFILSH.RTI file in the windows directory are not in sync. You can delete the DSKFILSH.RTI and not have to install a new key. The software will recreate the DSKFILSH.RTI if it is not there."

Problem:While trying to install key receive error:

Seat count is too low to transfer current reserved seats to new key

Cause:

The new key has less seats then are currently in use.

Solution:

You either have to exit out of the application which might result in loss of seat usage for the reminder of the time or you can setup the batch command to install the new key at a later time at night when the other key expires and everybody exited the application.

Problem:Message: SPLMFailed: [connecting socket] Connection refused – servername

Cause: Licensing service not started

Solution – check Install and start licensing service in Install and remove options or my computer – services

Check port 807 – firewall

check if the port 807 is available for pdlice in your Citrix Server is doing the following: 1) Open DOS Window and key in: netstat -noa 2) Look under the LOCAL ADDRESS column for port 807 (for example: 0.0.0.0:807), check the Process ID(PID) under the PID colum 3) Open the Task MAnager, select processes and enable the PID column in View --> Select Columns Look for the PID reported in step 2 and it should be assigned to pdlice.exe

Problem:Message: SPLM Failed : Invalid Key. Mismatching parameters

Cause: the physical network adapter is disabled.

Solution: Enable the physical network adapter

In SPPID – no license server defined

Problem: Error "Run-time error 481, Invalid picture".

Cause:

temp folder is deleted

through DOS window: SET and check the folder for TEMP and TMP variables and make sure that folder exists.

Solution:

Create temp folder

More information about how to enable or disable this option:

Do not use temp folders per sessionRequirements:

At least Microsoft Windows XP Terminal Services

Location: Computer Configuration\Windows Components\Terminal Services\Temporary folders\

Specifies whether to prevent Terminal Services from creating session-specific temporary folders.

You can use this setting to disable the creation of separate temporary folders on a remote computer for each session. By default, Terminal Services creates a separate temporary folder for each active session that a user maintains on a remote computer. Unless otherwise specified, these temporary folders are in %USERPROFILE%\Local Settings\Temp\<sessionID>.

If the status is set to Enabled, per-session temporary folders are not created. Instead, users' temporary files are stored in a common Temp directory for each user on the server (by default, %USERPROFILE%\Local Settings\Temp).

If the status is set to Disabled, per-session temporary folders are always created, even if the administrator specifies otherwise in the Terminal Services Configuration tool.

If the status is set to Not Configured, per-session temporary folders are created unless otherwise specified by the server administrator

Problem:“Fatal SPLM failed: [Read Pipe] Garbled Data From SPLM (Client”)

Cause:

invalid version of SPLM on client –

e.g. could happen if customer install a PDS QF for 08.00.00.09 which was build with latest libraries and requires >=08.00.02.01.

Solution:

Upgrade client and server to 08.00.02.01

Problem:

Error “ -5009:0x8002802b" installing SPLM is some machines

Cause:

The problem seems to be related to the Install shield

Solution:

Rename the folders located in the following in "C:\Program Files\Common Files\InstallShield\Professional\RunTime"

Problem:Batch Iso seat not released

pdlice.exe is not in the exceptions list on the machine running the batch iso.

Ask the customer to make sure that pdlice.exe is in the exceptions list. Also check to see if pdsidf.exe is still in the task list (pdsidf.exe is the executable which actually takes the seat). If pdsidf.exe is still active, the error message should be 'Seat Not Recoverable -- Licensees Up'. Ask them to send us the scavenge report and also verify that the node name/tcpip combo for the batchiso machine in the report is correct.

Problem:PDLICE Failed: [Check Size] Server key File Improperly Modified - Reinstall –

This error occurs after the new key was successfully installed and the customer is trying to open PDS.

Cause:

1. unknown

2. pointing to incorrect location: Regedit --> HKEY_LOCAL_MACHINE --> SOFTWARE--> INTERGRAPH-->PDLICE_ETC--> Double-click on PDLICE_KEY_S and check the value it should be like: c:\windows\servlice.dat – verify the path

Solution:

Cleaned up machine (removing SW – registry , path and servlice.dat file. Rebooted and installed SPLM latest 08.00.02.01 – generated new machine id and installed new key.

The solution for the other problems, has been to remove the license key (pdlice -c), re-generate the machine id and install a new key.

To make certain that the license file was truly removed (BEFORE generating a new machine id), at a dos prompt enter:

more < c::SPLMLog

If the file is not there, you will get an error message that it cannot find the file. The license file MUST BE REMOVED for this to work. The software does not have to be removed and re-installed.

The problem was the server has McAffee products loaded

On a server running Terminal Server (application mode) you must set the server to install mode before installing the PDLICE license key. This is done from a command line by executing "change user /install". After the key is installed, change the mode back by executing "change user /execute" from a command prompt.

If it's not set to install mode, the pdlice_key_s value is set to
P:\Windows...., where the P: in my case is my home drive. Setting the server to install mode before installing the license key enables the entry to be made properly.

This is why it worked when I removed the software, then reinstalled it. The server automatically prompts you to set the server to install mode when you run an installation program - I didn't think of it for installing the license until I looked at the value of the registry entry

Problem:SPLM not working if PANDA Antivirus is installed.

Error: Connection reset by Peer

Solution:

After installing Panda, you have to enter Panda > Status>Security Protection Settings>Select Firewall>Select Programs with access to the network Settings>Turn off Automatically assign communication permissions. Then Add Program for pdlice.exe (inbound and outbound), license.exe (inbound and outbound), and pdshell.exe (inbound and outbound). Hopefully, by turning off, Automatically assign... you will be prompted on what to let through the firewall. I have NOT been able to get Panda to work if the machine is a license SERVER. It should be prompting when the machine is a license server and it does not seem to be working correctly.

Problem:Socket reset by peer

Solution: remove bmwebcfg.exe

I should add that the offending component comes from a company called ByteMobile. If you run process explorer you should see a process called bmwebcfg.exe if you do a google search you will get a lot of hits and a lot of PC tools that will remove it for you,etc.

Besides the air cards I don't know whatever applications may load it, but any time you get the message about socket reset by peer on the server, I would look for this particular executable, to see if it is the same problem.

Problem:Error: COULD NOT SET INSTALL DATE

While loading SPLM software (Not the License) we are getting error message "COULD NOT SET INSTALL DATE": The error message has been enclosed for your reference. (SPLMsnap.jpg). The registry entry and operating system detail also has been enclosed in snap_reg doc file
Before installing SPLM we had removed PD_License server which was there on that server.

Solution: After reinstalling the SP2 the problem got solved.

Problem:Error scavenging: Connection reset by peer

Connection reset by peer – unable to scavenge license

Solution:

Firewall on client not setup properly (port 807, pdlice in exception list or IP address changed.

Machine not turned on

Problem:Error claiming a seat : Connection reset by peer

Connection reset by peer – unable to obtain license

Solution:

UNC path was specified in Log product usage. This will be fixed in 9.0 until then don’t use UNC path

Problem: License Database Locked By Another Process

When a new license key is installed with PDS users working and the SPLM software is left open, when the user close PD_Shell they get the following errors:

- License Database Locked By Another Process

- Error releasing seat - Please exit

Solution:

License need to be released with the scavenge command.

Close SPLM software after installing the license key.

Same error occurs if scavenge interferes with new license request. Simply try again.

Problem: Error –701 Occurred on OS local set to Korean, SPLM is NOT internationalized yet.

Remove key – uninstall SPLM – reboot – set language to English – install SPLM create new machine id – new key – also check path to windows – lok out foie strange characters.

-701 License file on machine is invalid - zero size and nonexistent (file in registry)

means that they deleted the previous license key.

There is a hidden file on a license server. This message means that this file is bad --

(1)they removed the license which deletes the file (not good with SPLM license server because the machine ID is stored here ) or

(2)the file does not exist (they didn't install SPLM and run GenerateMachineID on a non-PD_Lice license server).

If (1) occurred, then the only way to fix this is to generate a new machine id and send them a new key.

If (2) occurred, then the only way to fix this is to install SPLM, generate a new machine id and send them a new key.

If the customer has a PD_Lice license server, runs generate machine id (there is a registry entry written for machine id in this case and not a license file change since PD_Lice is already using it), removes pdlice, installs splm, then installs the key, he should not be getting -701 message

Other Install Key Error Codes:

-101 Process (Computer) Identifier does not match key.

-201 Network Identifier does not match key.

-301 Disk Identifier does not match key.

-401 Guid generated by hardware verification does not match key. (means that they re-ran Generate Machine ID AFTER sending us machine id for the key. There is no way to correct this problem without getting a new machine id.)

-501 SPLMid key is not in registry and license file is OLDer version.

-601 PD_Lice Current Version key is not in registry

Error: Connecting Socket Timed Out

1.) Stopping and starting service

2.) Server was still pointing at same server but it had record of old IP address. Unpointed server then repointed to current machine which worked fine.

If SPR doesn’t start but seats are available and the message complains about missing SRM keys:

use START>PROGRAMS>SPR>SELECT MODULES and UnCheck all the modules.

Incorrect number of seats reported:

SPLM always shows the Total Seats Currently Checked Out as 2 more than the actual number listed in the details, etc.

Even if no seats are checked out, it still shows 2.

There was a bug in the first 8.0 release that caused this mismatch. If I remember correctly, it was fixed in 8.0.2. It doesn't really hurt anything, but the only way to get rid of it is to UNINSTALL key, then regenerate machine ID and receive a new key. The error could re-apear when the next new key is installed with the older 8.0 version over the existing key.

转载于:https://blog.51cto.com/20194/483420

smartplant license manager issue相关推荐

  1. matlab错误103 577,小编为你作答win7系统安装MATLAB出现 license manager error 103错误的还原教程...

    win7旗舰版是用户量最大的一款操作系统:有不少人在使用中都遇见了win7系统安装MATLAB出现 license manager error 103错误的问题,相信很多朋友是人生中第一次碰到win7 ...

  2. ANSYS FLEXlm License Manager的卸载方法

    卸载ANSYS之后,ANSYS FLEXlm License Manager在"添加/删除程序"中无法卸载,根据中教程的启发,大概分为以下几步. 1. 在LMTOOLS中停止服务 ...

  3. ArcGIS License Manager 相关总结

    LicensenManager10.2启动失败解决方法 今天安装ArcGIS 10.2 时,刚按照百度经验装完ArcGIS LicenseManager时,就出现了众多网友都出现的问题,License ...

  4. ArcGIS License Manager 更新

    使用硬件锁的用户经常会碰到License管理服务相关的问题,例如合上笔记本进入休眠状态再打开时,硬件锁重新插入,ArcGIS License服务重启才能继续使用ArcGIS Desktop,给使用带来 ...

  5. 安装 | MatlabR2019b: License Manager Error -8. License checkout failed.

    博主github:https://github.com/MichaelBeechan 博主CSDN:https://blog.csdn.net/u011344545 最近在安装MATLAB2019b, ...

  6. 解决matlab2018a安装后遇到matlab license manager error -8

    安装包及教程:传送门 基础教程:传送门 在安装完成后,按照教程安装并将所需文件复制到相应文件中,然后回到桌面打开matlab显示 matlab license manager error -8 的错误 ...

  7. 如何解决远程windows服务器安装matlab出现License Manager Error-103问题

    最近在实验室的一台windows服务器上安装matlab的时候遇到一个问题,License Manager Error-103: 因为安装包之前在多台本地计算机上安装过都没有问题,后来经过查找,发现是 ...

  8. arcgis desktop 10.1 license manager无法启动问题解决

    arcgis desktop 10.1 license manager无法启动问题解决 参考文章: (1)arcgis desktop 10.1 license manager无法启动问题解决 (2) ...

  9. matlab7.0.4 license,MATLAB 7.0安装??License Manager Error-9~唉

    该楼层疑似违规已被系统折叠 隐藏此楼查看此楼 好不容易安装好,一执行就遇到了License Manager Error-9~ 依照网路上的方法也失败 (用Volumeid改硬盘序列号(SN号)改为li ...

  10. ArcGIS License Manager许可升级的方法及无法读取许可问题

    License Manager许可升级问题 将 License Manager 软件从 10.1 - 10.4 升级至 10.4.1 ArcGIS 10.1-10.4 许可可与 ArcGIS 10.4 ...

最新文章

  1. 【云计算】6_云数据库产品介绍
  2. Filter和Listener-学习笔记04【监听器】
  3. mybatis报错解决办法 :Result Maps collection does not contain value for java.lang.String
  4. 织梦dedecms默认网站地图sitemap.html优化
  5. 数字图像处理图像反转的实现_反转8位数字| 8085微处理器
  6. cpu是32位的 这指的是数据总线还是地址总线是32条?另外,电脑操作系统是3位的这指的是什么意思?指令是32...
  7. 【论文写作】本科、硕士研究生毕业论文格式问题
  8. python numpy : list VS np.array
  9. 阶段3 3.SpringMVC·_01.SpringMVC概述及入门案例_08.RequestMapping注解的作用
  10. Java程序性能优化
  11. 软件工程---gjb438b 质量规范体系
  12. Unix时间和leap seconds(闰秒)简要分析
  13. SVN提交文件失败:系统找不到指定路径
  14. GrabCut提取图像前景色MATLAB代码实现(含解释说明)
  15. 重装电脑麻烦,但值得
  16. 是否能任取前序、中序和后序两种序列建立二叉树?
  17. vue-router 路由 pushstate replacestate popstate 详解
  18. 转:著名的100个管理定律点评2 -- 以人为本的人性化管理
  19. 《算法导论》第16章 贪心算法 个人笔记
  20. 输入一个双精度浮点数,输出这个浮点数的%f结果、保留5位小数的结果、%e、%g格式的结果

热门文章

  1. linux平台上不同类型的压缩文件的压缩与解压
  2. 全网首发:JDK绘制文字:八、绘制函数简要分析
  3. so运行出错:只包含了头文件,未同时编译cpp
  4. 全网首发:TeaVM编译时容易出错的几种代码
  5. LINUX编译OpenJDK8:cc1plus: all warnings being treated as errors
  6. Git第一次提交代码的操作
  7. LINUX获取当前用户及信息的命令
  8. C/C++混编“未定义的引用”的解决一例
  9. LINUX查看一个进程用的内存准确数量
  10. 只能用光盘启动怎么办?