本文描述几个命令行界面(CLI)命令,以及其他排除故障技术,可帮助排除硬盘驱动器(HDD)问题故障。排除的HDD问题故障佳方法是使用LED, GUI、BIOS, LSI选项ROM/MegaRaid GUI和日志。然而,这些选项总是不是可用的。在这种情况下,您能使用CLI。

There are no specific requirements for this document.

This document is not restricted to specific software and hardware versions.

The information in this document was created from the devices in a specific lab environment.All of the devices used in this document started with a cleared (default) configuration.If your network is live, make sure that you understand the potential impact of any command.

Refer to Cisco Technical Tips Conventions for more information on document conventions.

Note:在本文列出的某些命令取决于,如果有一个LSI MegaRaid控制器,当不是1064/1068e LSI控制器支持所有。

输入显示PCI适配器命令为了查看产品名称。此示例显示一台LSI 1064e适配器。

ucs-c2xx-m1 /chassis #show pci-adapter

Slot Vendor ID Device ID SubVendor ID SubDevice ID Product Name

---- --------- --------- ------------ ------------ ------------------------

M 0x1000 0x0056 0x152d 0x896d Cisco LSI 1064E Mezzan...

输入显示hdd命令为了查看HDDs的状态。

ucs-c2xx-m1 /chassis #show hdd

Name Status

-------------------- --------------------

HDD_01_STATUS present

HDD_02_STATUS absent

HDD_03_STATUS absent

HDD_04_STATUS absent

输入显示虚拟驱动器命令为了查看虚拟驱动器的状况。因为不要求您关闭服务器和输入BIOS查看信息,此命令是有用的。

ucs-c210-m2/chassis #scope storageadapter SLOT-5

ucs-c210-m2/chassis/storageadapter #show virtual-drive

Virtual Drive Status Name Size RAID Level

-------------- ------------------ ---------------------- --------- ----------

0 Optimal 139236 MB RAID 1

1 Degraded 974652 MB RAID 5

输入显示物理驱动命令为了查看物理驱动的状况。

ucs-c210-m2 /chassis/storageadapter #show physical-drive

Predictive

Slot Failure Drive Coerced

Number Controller Status Manufacturer Model Count Firmware Size Type

------ ---------- ------ ------------ ----------- ---------- -------- --------- ----

0 SLOT-5

1 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD

2 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD

3 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD

4 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD

5 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD

6 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD

7 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD

9 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD

10 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD

输入显示错误计数器命令为了查看可校正和无法修复的错误的数量。

ucs-c210-m2 /chassis/storageadapter #show error-counters

PCI Slot SLOT-5:

Memory Correctable Errors: 0

Memory Uncorrectable Errors: 0

输入显示HW设置命令为了查看RAID控制器配置。

ucs-c210-m2 /chassis/storageadapter #show hw-config

PCI Slot SLOT-5:

SAS Address 0: 500e004aaaaaaa3f

SAS Address 1: 0000000000000000

SAS Address 2: 0000000000000000

SAS Address 3: 0000000000000000

SAS Address 4: 0000000000000000

SAS Address 5: 0000000000000000

SAS Address 6: 0000000000000000

SAS Address 7: 0000000000000000

BBU Present: true

NVRAM Present: true

Serial Debugger Present: true

Memory Present: true

Flash Present: true

Memory Size: 512 MB

Cache Memory Size: 394 MB

Number of Backend Ports: 8

输入显示物理驱动计数命令为了查看HDDs的编号。

ucs-c210-m2 /chassis/storageadapter #show physical-drive-count

PCI Slot SLOT-5:

Physical Drive Count: 9

Critical Physical Drive Count: 0

Failed Physical Drive Count: 0

在不访问CLI情况下,您能查看技术支持文件(/tmp/tech_support)为了得到关于HDDs的状态的信息。这是摘自显示从智能平台管理接口的技术支持文件的一个部分(IPMI)传感器的HDDs :

Querying All IPMI Sensors:

Sensor Name | Reading | Unit | Status | LNR | LC | LNC | UNC | UC | UNR

HDD0_INFO | 0x0 | discrete | 0x2181 | na | na | na | na | na | na

HDD1_INFO | 0x0 | discrete | 0x2181 | na | na | na | na | na | na

HDD2_INFO | 0x0 | discrete | 0x2181 | na | na | na | na | na | na

HDD3_INFO | 0x0 | discrete | 0x2181 | na | na | na | na | na | na

HDD4_INFO | 0x0 | discrete | 0x2181 | na | na | na | na | na | na

HDD5_INFO | 0x0 | discrete | 0x2181 | na | na | na | na | na | na

HDD6_INFO | na | discrete | na | na | na | na | na | na | na

HDD7_INFO | na | discrete | na | na | na | na | na | na | na

这是摘自显示HDD状态的细分的技术支持文件的一个部分:

Bit[15:10] - Unused

Bit[9:8] - Fault

Bit[7:4] – LED Color

Bit[3:0] – LED State

Fault:

0x100 – On Line

0x200 - Degraded

LED Color:

0x10 – GREEN

0x20 – AMBER

0x40 – BLUE

0x80 – RED

LED State:

0x01 – OFF

0x02 – ON

0x04 – FAST BLINK

0x08 – SLOW BLINK

这是摘自显示HDD状态的技术支持文件的一个部分(与0x2181状态码) :

0x2181

Fault:

0x100 --- HDD is On Line

LED Color:

0x80 --- RED

LED State:

0x01 --- OFF

您有选项使用备用电池单元(BBU)以一些服务器部署。BBU是在断电期间,保护磁盘关于RAID控制器的写高速缓存数据72小时的一个智能备用电池单元。

此示例显示如何使用MegaCli为了检查BBU的状态:

bash$ sudo /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -a0 -NoLog

Password:

. . .

Battery Replacement required : Yes

. . .

Relative State of Charge: 99 %

Absolute State of charge: 76 %

. . .

Date of Manufacture: 11/08, 2008

Design Capacity: 700 mAh

Design Voltage: 3700 mV

Specification Info: 33

Serial Number: 243

Pack Stat Configuration: 0x6cb0

Manufacture Name: LSI113000G

Device Name: 2970700

Device Chemistry: LION

Battery FRU: N/A

此示例显示如何使用CLI为了检查BBU的状态:

ucs-c200-m2 /chassis/storageadapter #show bbu detail

Controller SLOT-7:

Battery Type: iBBU

Battery Present: true

Voltage: 4.023 V

Current: 0.000 A

Charge: 100%

Charging State: fully charged

Temperature: 34 degrees C

Voltage Low: false

Temperature High: false

Learn Cycle Requested: false

Learn Cycle Active: false

Learn Cycle Failed: false

Learn Cycle Timeout: false

I2C Errors Detected: false

Battery Replacement Required: true

Remaining Capacity Low: true

联想服务器显示屏显示HDD2,UCS C系列安置服务器排除的HDD问题故障CLI命令相关推荐

  1. 思科服务器型号m1414,Cisco UCS M 系列模块化服务器

    特点和功能 当今的云应用需要有另一种更好的架构.计算功能需要从基础架构中抽离出来,才能提升密度,实现更轻松的扩展,并为管理.效率和性能提供完美的设计. UCS M 系列模块化服务器在设计上着眼于高度并 ...

  2. 联想服务器显示屏显示HDD2,联想电脑开机进入boot menu界面怎么办 带你快速解决一下...

    1.按ESC键退出启动界面: 2.在当前界面选择硬盘HDD或其它启动设置回车确定后启动电脑. 联想笔记本开机出现BOOT MENU和APP MENU这很可能是三个原因:第一个原因:就是开机的时候无意中 ...

  3. 思科服务器管理口装系统,cisco思科统一计算系统UCS B系列刀片服务器推荐

    如今,融合基础架构可谓大行其道,其能够整合系统,缩短部署时间,提高资源利用率并降低成本,得到了企业用户的广泛认可.作为融合基础架构的核心关键的计算平台,刀片基础架构则可以在机箱层面中实现很好的整合功能 ...

  4. 思科ucs-b系列服务器,思科统一计算系统UCS B系列刀片推荐

    Cisco UCS B250 M2 Cisco UCS B250 M2 扩展内存刀片服务器有助于最大限度地提高要求最严格的虚拟化和大型数据集应用程序的性能和容量.这是一款全宽.双路的刀片服务器,其吞吐 ...

  5. 服务器不能显示中文,彻底解决delphi WebBroker服务器中文乱码 delphi WebBroker服务器不能显示中文网页 WebBroker中文显示乱码...

    彻底解决delphi WebBroker服务器中文乱码 彻底解决WebBroker中文显示乱码 彻底解决delphi WebBroker服务器不能显示中文网页 这个问题被折腾惨啦! 网上一大堆,就没能 ...

  6. 服务器上显示叹号是什么意思,服务器上显示黄色叹号

    服务器上显示黄色叹号 内容精选 换一换 当在服务器上成功部署SSL证书后,通过https://+域名的方式访问网站时,显示无法打开网站.可能原因一:未开启443端口可能原因二:配置文件未配置正确请根据 ...

  7. 魔兽世界服务器不显示角色信息,网易公告:部分服务器限制新角色创建功能

    自<魔兽世界:大地的裂变>开放以来,玩家高涨的热情极大地鼓舞了我们,许多服务器均呈现一片繁荣景象.为了给大家更好的游戏体验,让所有的玩家都能拥有一个更加平衡和优异的游戏环境,我们在近期将根 ...

  8. 服务器上显示存储脱机,使存储空间直通服务器脱机以进行维护

    使存储空间直通服务器脱机以进行维护 10/08/2018 本文内容 适用于: Windows server 2022.Windows server 2019 Windows Server 2016 本 ...

  9. mc服务器一直显示检测中,我的世界服务器一直显示登入中怎么办

    许多玩家在玩我嘚世界嘚时候出现了,白.水碧.花紅,dnf新闻,raise father's ,. 情熱は海,服务器一直显示登入中嘚綪况,かない. 調和がとれて, you and I have beco ...

最新文章

  1. loss函数为何选交叉熵
  2. Java的equals() 和 hashCode()
  3. 走财运健步——青龙羊毛
  4. QT中在终端下写个小例子
  5. 1839行政领导学 (2)
  6. 计算机视觉实习面经【微软/阿里/腾讯】
  7. 奇安信代码卫士帮助微软修复多个高危漏洞,获官方致谢
  8. Java aio(异步网络IO)初探
  9. python版本安装
  10. Image Style Transfer:多风格 TensorFlow 实现
  11. Visio画图允许两条线交叉的操作
  12. 手机计算机文件夹加密文件,手机文件夹加密锁软件加密步骤【图文教程】
  13. 挑战年薪50万不是梦,你要的高级架构师课程来袭!
  14. 电脑重装系统后,重启时遇到错误,报错需要重新启动,并重新安装系统
  15. 校园助手APP--登陆
  16. Python分布式爬虫打造搜索引擎
  17. php整型的最大值,php整型(Integer)
  18. python求15的因数_十五道Python小案例,学会这些,Python基础已过关!
  19. 第九届河南省程序设计大赛 D 导弹发射
  20. docx和doc有什么区别

热门文章

  1. 音响指标中常见的几种dB
  2. Android使用百度定位不精确问题
  3. D3.js 第13课 饼状图
  4. 让 WSL2 中的 Kali 虚拟机使用无线网卡
  5. 主机迁移上云 - 文件级别
  6. MEID简介 ESN
  7. 仓库管理系统/课程设计/ASP.NET/
  8. 论文学习记录20200605:隐私保护神经网络推理[USENIX2020]
  9. 软件日语单词(应试用)
  10. 网络协议逆向工具Netzob1.0.2的安装与试用