Demystifying Ethernet Types— Difference between Cat5e, Cat 6, and Cat7

Ethernet represents the plumbing pipes of the Internet. Many network installers and system integrators are familiar with the ethernet types: Cat5e and Cat6 cables with RJ45 connectors. But the term “Ethernet”, co-invented by Robert Metcalfe, encompasses an entire range of twisted pair and fiber cables that are constantly being upgraded and standardized by the Institute of Electrical and Electronics Engineers known as IEEE. Each new iteration of Ethernet, or category, supports increasingly faster bandwidth speeds and improves upon noise cancelation.

Build a Co-Axial Based Network

Cross sections of different category types of Ethernet reveal differing internal physical compositions. This guide will help you learn more about the subtle differences between each generation of twisted pair Ethernet cable.

Different Ethernet Categories

Ethernet cabling differences can be invisible to the casual observer. However, each new generation introduces copper pairs with tighter twists and more complex sheathing. Many earlier Ethernet generation cables have become obsolete.

Category 3

Cat3 cable is an earlier generation of Ethernet but can still be seen in older deployments. With the ability to support a maximum frequency of 16 MHz, this type of Ethernet can still be used for two-line telephone systems and 10BASE-T networks. CAT3 cable can also be used for alarm system installation or similar applications. CAT3 cable can have 2, 3, or 4 copper pairs (though uncommon). Category 5e cable, however, has become the default Ethernet category of choice with the ability to support faster speeds and frequencies.

Category 5

Cat5 Ethernet, introduced 10/100 Mbps Ethernet over distances of up to 100 meters, also known as Fast Ethernet. Even though some older deployments still use CAT5 cable, it is now considered obsolete and has since been replaced by Cat5e.

NOTE: 100 Mbps /100m.

Category 5e

Though Cat5 and Cat5e cables are physically similar, Category 5e Ethernet adheres to more stringent IEEE standards. “E” is for enhanced, meaning a lower-noise version where the potential for crosstalk is reduced. Crosstalk is interference that transfers from adjacent wires.

Cat5e is the most common type of cabling used for deployments due to its ability to support Gigabit speeds at a cost-effective price. Even though both Cat5 and Cat5e support a maximum frequency of up to 100MHz, Cat5e has completely replaced its predecessor. Gigabit Ethernet utilizes 4 data pairs in comparison to Fast Ethernet which utilizes 2 data pairs.

Further, Cat 5e supports speeds of up to 1000 Mbps. It’s flexible enough for small space installations like residences, though it is still used in commercial spaces. Of all the current cabling options, Cat5e is your least expensive option.

NOTE: 100-250Mhz/1 Gbps/100m.

Category 6

Cat6 wiring can support up to 10 Gbps and frequencies of up to 250 MHz. While Cat5e cable features 1.5-2 twists per cm, Cat6 cables are more tightly wound and feature 2 or more twists per cm. (The amount of twists per cm varies upon each cable manufacturer).

Cat6 cables also sport thicker sheaths in comparison to Cat5e. Though standard Ethernet supports distances of up to 100 meters, CAT6 cable only supports 37-55 meters (depending on crosstalk) when transmitting 10 Gbps speeds. Its thicker sheath protects against Near End Crosstalk (NEXT) and Alien Crosstalk (AXT).

Even though Cat6 and Cat6a cabling offer higher performance rates, many LANs still opt for CAT5e due to its cost-effectiveness and ability to support Gigabit speeds.

NOTE: 250-500Mhz/10 Gbps /100m.

Category 6a

Cat6a supports bandwidth frequencies of up to 500 MHz, twice the amount of Cat6 cable, and can also support 10Gbps like its predecessor. However, unlike Cat6 cabling, Cat6a can support 10 Gigabit Ethernet at 100 meters. [Cat6 cabling on the other hand, can transmit the same speeds at up to 37 meters.]

Cat6a also features more robust sheathing which eliminates alien crosstalk (AXT) and improves upon the signal-to-noise ratio (SNR). “A” = augmented. The stronger sheathing makes Cat6a cabling considerably thicker than Cat6, also making it less flexible to work with, and therefore, better suited for industrial environments at a lower price point.

NOTE: 250-500Mhz/10 Gbps /100m.

Category 7

Cat7 can also support 10 Gbps, but laboratory testing has successfully shown its ability to transmit up to 40 Gb at 50 meters and even 100 Gb at 15 meters. The newer “Class F” cabling can support frequencies of up to 600 Mhz. That said, Cat7 has not been approved as a cable standard for telecommunications.

Cat7 offers extensive shielding to reduce signal attenuation and is relatively stiff in comparison to previous generations of cabling. Both individual pairs are shielded, with an additional layer of shielding over the entire cable. The shielding needs to be grounded and Cat7 also requires special GigaGate45 (GG45) connectors to take full advantage of higher performance features.

All in all, Cat6a can perform just about the same as Cat7 but at a lower price point. Most of our AV and IP surveillance customers opt for Cat6a STP or Cat6a FTP. Both offer shielding from alien crosstalk and interference around high voltage lines.

Cat7 is suited for use in datacenters and large enterprise networks.

Note: 600Mhz/10Gbps/100m (40Gbps at 50m/100Gbps at 15m).

Category 8

Cat8 cable is still in the development stage and not yet ratified. According to the 2016 Ethernet Alliance Roadmap, it will be able to support 25GB and 40Gb Ethernet. Cat8 will be able to support even faster transmission rates at distances of up to 30 meters.

How to know what types of ethernet cabling to buy once deciding on a CAT type

Answer the following questions to narrow down to your requirements:

• Are you looking for burial cables with UV protection?

• Will the cables be within 6 inches of power lines?

• Will the cables be in walls?

• Is flame resistance cabling required for the installation?

Here’s a link to an outdoor CAT6 gel filled cable. There are plenty of good manufacturers out there. FlyinFiber is not advocating one supplier. This is just to illustrate.

Each cable category has various types of insulation or shielding that installers need to take into consideration before purchasing. There’s no one answer to all questions but the answers to these questions should help the reader decide based on their project.

The price difference between the various types can range anywhere from $100 to $600+ depending on type.

Here’s a helpful overview: Siemon’s category 6A F/UTP shielded outside plant (OSP) cable delivers TIA and ISO performance requirements for shielded category 6A/class EA.

Why are copper pairs twisted?

When telephone lines were first deployed alongside power lines, Alexander Graham Bell, popularly known as the inventor of the telephones, was the first person to twist copper pairs to reduce crosstalk between the lines. Twisting the copper cable every 3-4 utility poles allowed for the reduction of electromagnetic interference and an increase in range. Ethernet copper cables adopted the same technique to reduce crosstalk between internal wires (XT) and external wires (AXT).

Shielded (FTP) vs. Unshielded (UTP)

Twisted pair copper comes in shielded an unshielded forms. Shielded copper cable includes protective conductive coating such as braided strands of copper, copper tape or conductive polymer to reduce noise interference. Unshielded Twisted Pair, or UTP, includes no shielding and is ideal for most common LAN environments. Shielded twisted copper pairs, are reserved for networking environments with higher frequencies.

There are many types of shielded copper pairs. Sheathing can also envelop all four data pairs. Sheathing can wrap around twisted pairs.There are two sections to a shielded “code”. The first letter signifies the type of shield used to enclose all four twisted pairs of an Ethernet cable. An Unshielded cable is marked with a (U), a cable with Foil Shielding is marked with an (F), and a cable with Braided Shielding is marked with an (S). The second portion of the code, describes if a twisted pair is foiled (F) or Unfoiled (U). TP stands for Twisted Pair.

Shielding Code:

TP: Twisted Pair

U: Unshielded or Unscreened

F: Foil Shielding

S: Braided Shielding

Types of Shielded Ethernet Cables

F/UTP– Foiled/Unshielded Twisted Pair

Common in Fast Ethernet deployments, this cable will have a foil shield that wraps around unshielded twisted pairs.

S/UTP– Braided Shielding/ Unshielded Twisted Pair

This cable will wrap a braided shield around unshielded twisted pairs.

SF/UTP– Braided Shielding+Foil/Unshielded Twisted Pairs

This cable braids a shield around a foil wrap to enclose unshielded twisted pairs.

S/FTP– Braided Shielding/Foiled Twisted Pair

This cable wraps a braided shield around all four copper pairs. Additionally, each twisted pair is enveloped in foil.

F/FTP-Foiled/Foiled Twisted Pair

This cable encloses all copper pairs in foil. Additionally, each twisted pair is enveloped in foil.

U/FTP-Unshielded/Foiled Twisted Pairs

This cable only envelopes the twisted pairs in foil.

U/UTP-Unshielded/UnshieldedTwisted Pair

No sheathing is used. Standard Cat5e cable are examples of U/UTP cables.

Solid vs. Stranded Ethernet

These terms refer to Ethernet conductors. Stranded copper cables comprise of several thin copper cables. Solid cable conductors comprise of a single, thick copper cable conductor.

At the end of this article, we must say,the above content comes from flyinfiber collection, because flyinfiber’s customers include a large number of on-site construction technicians, hoping that this content can help customers better use Cats.

Demystifying Ethernet Types— Difference between Cat5e, Cat 6, and Cat7相关推荐

  1. S32K148开发板Ethernet相关内容

    最近在做一些关于S32K148开发板的使用,研读了部分该开发板关于ENET模块的官方文档. 2 Ethernet MAC (ENET) 2.1 Chip-specific ENET informati ...

  2. pandas强大的Python数据分析工具

    指数 模块 | 下一页 | 熊猫0.22.0文档 » 目录 什么是新的 安装 贡献给大熊猫 包概述 10分钟到熊猫 教程 食谱 数据结构简介 基本的基本功能 使用文本数据 选项和设置 索引和选择数据 ...

  3. autoconf 英文手册

    1 Introduction A physicist, an engineer, and a computer scientist were discussing the nature of God. ...

  4. python操作三大主流数据库(6)python操作mysql⑥新闻管理后台功能的完善(增、ajax异步删除新闻、改、查)...

    python操作mysql⑥新闻管理后台功能的完善(增.删.改.查) 安装表单验证 D:\python\python_mysql_redis_mongodb\version02>pip inst ...

  5. CentOS命令行安装配置KVM详细教程

    系统为centos 6.4 64位 最小化安装  服务器为dell R720,所以网卡为em0,在vmware作为练习安装学习,同样可以,命令行不是为了显的牛B,而是不用考虑桌面兼容性和其他原因的影响 ...

  6. CloudStack 配置高级网络简明手册

    玩过CloudStack的朋友都知道,新建区域(Zone)的时候,会有两个选项: 1 基本网络: 提供一个网络,将直接从此网络中为每个 VM 实例分配一个 IP.可以通过安全组等第 3 层方式提供来宾 ...

  7. Nginx基本功能及其原理

    一.什么是正向代理和反向代理: A同学在大众创业的大时代背景下开启他的创业之路,目前他遇到的最大的一个问题就是启动资金,于是他决定去找马云爸爸借钱,可想而知,最后碰一鼻子灰回来了,情急之下,他想到一个 ...

  8. java脚本含义_set -e在bash脚本中的含义是什么?

    这是一个老问题,但这里没有一个答案讨论在Debian包处理脚本中使用 set -e aka set -o errexit . 根据Debian政策,这些脚本中必须使用此选项;意图显然是为了避免任何未处 ...

  9. c++primer 第2章 练习题答案 (尚未完善 陆续补充中 基本上已经完成)

    short int 2个字节 int 2/4字节 long 4/8字节 long long 8字节 其实这个吧 意义不是太大 基本上现在大多数都32/64位机器 所以int基本上最小就都4个字节了  ...

最新文章

  1. Kotlin setText 使用
  2. LiveVideoStackCon 音视频技术大会 2022 上海站日程发布啦!
  3. Ubuntu12.04下解决sudo apt-get update警告Duplicate sources.list entry
  4. 单片机复位电路电容一定用电解电容_什么叫51单片机最小系统
  5. RocketMQ集群特点
  6. 紧急通知!最新版CleanMyMac X月底倒计时清仓冲量!
  7. String.IsNullOrEmpty()方法以及C#中的示例
  8. OleDbCommandBuilder 使用方法
  9. mysql数据库表分区_MySQL数据库之MySQL的分区和分表详解
  10. linux运维实战练习-2015年8月30日课程作业(练习)安排
  11. 设计一个扩展自抽象类geometricobject_设计模式4之模板方法模式
  12. 可变参数函数——以printf为例子
  13. 测试类报错:空指针异常
  14. pdf转换器免注册码
  15. STM32单片机学习总结之------位操作
  16. 本周大新闻|PS VR2已确认20款大作,Magic Leap 1低价清库存
  17. maya中英文对比_[转载]maya中英文对照
  18. Discuz大气游戏风格模板/仿lol英雄联盟游戏DZ游戏模板GBK
  19. 初等变换:矩阵与行列式
  20. mysql fixed数据类型_MySQL数据类型有哪些?MySQL数据类型详解

热门文章

  1. TMS320F28335调用官方库进行FFT频谱分析
  2. 应聘中巧用积极的心理暗示
  3. mysql存储图片的几种方式_PHPmysql存储照片的两种方式
  4. 微信小程序—相关配置
  5. Opencv实现Sift、Surf、ORB特征提取与匹配
  6. 2018总结----对共享单车的思考
  7. html按钮四钟状态,按钮.html
  8. 灰度共生矩阵的原理及代码实现(python)
  9. 制作抖音超火的罗盘时钟(HTML+CSS+JS)
  10. Unity开发VR——结合VRTK(一)