Cable and Board Presence - Message Code: "x1Axx" | ||||||
---|---|---|---|---|---|---|
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Phase When Event Can Occur? |
E1A10 | PDBPwrCable | High | PDB power cable to the planar is missing or bad and system will not power on. | Failing device is reseated/replaced/repaired. | Yes | Pre-Post |
E1A11 | PCIRsrConfig | High | PCI risers are not configured correctly; some invalid configurations prevent system power on. | Failing device is reseated/replaced/repaired. | Yes | Pre-Post |
E1A12 | PCIRsrMissing | High | One or all of the PCI risers is missing. This prevents system power on. | Failing device is reseated/replaced/repaired. | Yes | Pre-Post |
E1A14 | SAS Cable A | Low | SAS cable A is missing or bad. | Failing device is reseated/replaced/repaired. | Yes | Any |
E1A15 | SAS Cable B | Low | SAS cable B is missing or bad. | Failing device is reseated/replaced/repaired. | Yes | Any |
E1A16 | SAS Cable FB | Low | Flex bay SAS cable is missing or bad. | Failing device is reseated/replaced/repaired. | Yes | Any |
E1A17 | PwrCable FB | Low | Flex bay power cable is missing or bad. | Failing device is reseated/replaced/repaired. | Yes | Any |
E1A18 | PDBCtrl Cable | High | PDB control cable to the planar is missing or bad and system will not power on. | Failing device is reseated/replaced/repaired. | Yes | Any |
Temperature - Message Code: "x11xx" | ||||||
---|---|---|---|---|---|---|
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Phase When Event Can Occur? |
E1114 | Temp Ambient | Med | Ambient temperature has a reached a point outside of the allowed range. | Temperature returns to allowable range. | Yes | Any |
E1116 | Temp Memory | High | Memory has exceeded allowable temperature and has been disabled to prevent damage to the components. | AC Cycle or SEL clear | Yes | Any |
Voltages - Message Code: "x12xx" | ||||||
---|---|---|---|---|---|---|
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Phase When Event Can Occur? |
E1210 | CMOSBatt | Low | CMOS battery is missing or the voltage is outside of the allowable range. | Failing device is reseated/replaced/repaired. | Yes | Any |
E1211 | ROMBBatt | Low | PERC5I RAID battery charger has reported to the Server Management that the battery is either missing, can't charge the battery (possibly because of high temperatures), or the battery is bad. | Failing device is reseated/replaced/repaired. | Yes | Any |
W1228 | ROMBBatt< 24 hr | Low | This is a predictive failure warning message telling the user that the PERC5I RAID battery has less then 24 hours of charge left init. We provide this message as a warning message to the customer. | Battery charges to > 24 hours of sustained charge. | Yes | Any |
E1214 | 1.5VPwrGd | High | 1.5 VV voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1215 | 1.8VPwrGd | High | 1.8 VV voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1216 | 3.3VPwrGd | High | 3.3 V voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1217 | 5VPwrGd | High | 5 V voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1218 | PCIRsr5VPwrGd | High | PCI Riser 5 V voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1219 | BackplanePwrGd | High | Backplane voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1221 | Flex BayPwrGd | High | Flex Bay voltage regulator power good has failed. | AC Cycle or SEL clear | Yes | Any |
E1222 | VCACHE #PwrGd | High | VCACHE # voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1223 | VRM #PwrGd | High | VRM # voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1225 | ESB 1.5VPwrGd | High | ESB 1.5 VV voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1226 | PCIRsr1.5VPwrGd | High | PCI Riser 1.5 VV voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1227 | LinearPwrGd | High | Linear voltage regulator(s) has failed. Represents status of multiple voltage regulators used in the video and LOM circuitry. | AC Cycle or SEL clear | Yes | Any |
E1228 | 0.9VPwrGd | High | Memory VTT voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E1229 | CPU # VCORE | High | Processor # VCORE voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E122A | CPU VTTPwrGd | High | Processor VTT voltage regulator has failed. | AC Cycle or SEL clear | Yes | Any |
E122B | 0.9 V Over Voltage | High | 0.9 V regulator voltage has exceeded the allowable voltage range. | AC Cycle or SEL clear | Yes | Any |
E122C | CPU Power Fault | High | A voltage regulator failure was detected when the processor regulator(s) was enabled. | AC Cycle or SEL clear | Yes | Any |
Fans - Message Code: "x13xx" | ||||||
---|---|---|---|---|---|---|
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Phase When Event Can Occur? |
E1310 | RPM Fan ## | Low | RPM of fan ## is outside of the intended operating range. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any |
E1311 | RPM Fan Mod #A | Low | RPM of fan A in the # module is outside of the intended operating range. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any |
E1311 | RPM Fan Mod #B | Low | Same as above except for fan B of module #. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any |
E1311 | RPM Fan Mod #C | Low | Same as above except for fan C of module #. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any |
E1311 | RPM Fan Mod #D | Low | Same as above except for fan D of module #. | Fan RPM reading returns to a point inside of the intended operating range. | Yes | Any |
E1313 | Fan Redundancy | Low | The system is no longer fan redundant. Another fan failure would put the system at risk of over-heating. | Fan redundancy is regained, which requires all fans to be operating within the intended operating range. | Yes | Any |
Processors - Message Code: "x14xx" | ||||||
---|---|---|---|---|---|---|
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Phase When Event Can Occur? |
E1410 | CPU # IERR | High | Processor # has had an internal error (IERR), but this does not always mean that CPU is the problem .There are a large variety of issues that cause an IERR. | AC Cycle or SEL clear | Yes | Any |
E1414 | CPU #Thermtrip | High | Processor # has encountered a Thermtrip(over-temperature) event. | AC Cycle or SEL clear | Yes | Any |
E1418 | CPU # Presence | High | Processor # is missing/bad and the system is in an unsupported configuration. | AC Cycle or SEL clear | Yes | Pre-POST |
E141C | CPU Mismatch | High | Processors are not compatible as defined by Dell .System is in an unsupported configuration. | AC Cycle or SEL clear | Yes | Pre-POST |
E141F | CPU Protocol | High | BIOS has reported a processor protocol error. | AC Cycle or SEL clear | Yes | POST, After POST |
E1420 | CPU Bus PERR | High | BIOS has reported a processor bus PERR (parity error). | AC Cycle or SEL clear | Yes | POST, After POST |
E1421 | CPU Init | High | BIOS has reported a processor initialization error. | AC Cycle or SEL clear | Yes | POST, After POST |
E1422 | CPU MachineChk | High | BIOS has reported a machine check error. | AC Cycle or SEL clear | Yes | POST, After POST |
System Memory - Message Code: "x21xx" | ||||||
---|---|---|---|---|---|---|
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Phase When Event Can Occur? |
E2110 | MBECrdx DIMM ## & ## | High | One of the DIMMs in the set implicated by "## & ##" has had a multi-bit error (MBE).If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z. | AC Cycle or SEL clear | Yes | POST, After POST |
E2111 | SBE Log DisableCrdx DIMM ## | High | BIOS has disabled memory single-bit error (SBE) logging and will not log anymore SBEE's until the system is rebooted.## represents DIMM implicated by BIOS .If no memory riser is present the “Crd x” string is left out of the message.“x” is the memory riser, A-Z. | System reset | Yes | POST, After POST |
E2112 | MemSpareCrdx DIMM ## | High | BIOS has spared the memory because it has determined the memory had too many errors.## represents DIMM implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z. | System reset | Yes | POST, After POST |
E2113 | Mem Mirror Crd x DIMM ## & ## | High | BIOS has disabled memory mirroring because it has determined one half of the mirror has had too many errors. ## & ## represents DIMM pair implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z. | System reset | Yes | POST, After POST |
I2114 | MemRaid | Low | BIOS Memory RAID Bank | User action, sensor return to normal | Yes | Any |
I2115 | MemAdded Card x | Low | Memory has been added while the system is running. | AC Cycle or SEL clear | Yes | Any |
I2116 | MemRemoved | Low | Memory has been removed while the system is running. | AC Cycle or SEL clear | Yes | Any |
E2117 | MemHot Plug | Low | Memory hot-plug operation has failed. | AC Cycle or SEL clear | Yes | Any |
E2118 | Fatal NBMemCRC | High | Northbound FBD CRC error on non-redundant entry. One of the connections in the FBD link on the Northbound (towards the MCH) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row. | AC Cycle or SEL clear | Yes | POST, After POST |
E2119 | Fatal SBMemCRC | High | FBD alert on non-redundant entry. One of the connections in the FBD link on the Southbound (towards the AMB'son the FBDIMM's) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row. | AC Cycle or SEL clear | Yes | POST, After POST |
Power Supplies - Message Code: "x16xx" | ||||||
---|---|---|---|---|---|---|
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Phase When Event Can Occur? |
E1610 | PS # Missing | Low | Power supply # was removed or is missing from the system. | Failing device is reseated/replaced/repaired. | Yes | Any |
E1614 | PS # Status | Low | Power supply # has failed. | Failing device is reseated/replaced/repaired. | Yes | Any |
E1618 | PS # Predictive | Low | Power supply # has a failure that predicts a power down event in this supply (i.e. power supply fan failure or power supply over-temp). | Failing device is reseated/replaced/repaired. | Yes | Any |
E161C | PS # Input Lost | Low | Power supply # is attached to the system but has lost its AC/DC input. | Failing device is reseated/replaced/repaired. | Yes | Any |
E1620 | PS #Input Range | Low | Power supply #'s AC/DC input is outside of the allowable range. | Failing device is reseated/replaced/repaired. | Yes | Any |
E1624 | PS Redundancy | Low | The power supply subsystem is no longer redundant. If the last supply fails the system will go down. | Failing device is reseated/replaced/repaired. | Yes | Any |
E1625 | PS AC Current | Low | The power supply input power is above the allowed amount for the power supply. | Failing device is reseated/replaced/repaired. | Yes | Any |
BIOS - Message Code: "x17xx" | ||||||
---|---|---|---|---|---|---|
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Phase When Event Can Occur? |
E1710 | I/O ChannelChk | High | BIOS has reported an I/O channel check. | AC Cycle or SEL clear | Yes | POST, After POST |
E1711 | PCI PERR B## D## F## | High | BIOS has reported PCI parity error on a component that resides in PCI configuration space at bus ##, device ##, function ##. | AC Cycle or SEL clear | Yes | POST, After POST |
E1711 | PCI PERR Slot # | High | BIOS has reported PCI parity error on a component that resides in slot #. | Same as above. | Same as above. | Same as above. |
E1712 | PCI SERR B## D## F## | High | BIOS has reported a PCI system error on a component that resides in PCI configuration space at bus ##, device ##, function ##. | AC Cycle or SEL clear | Yes | POST, After POST |
E1712 | PCI SERR Slot # | High | BIOS has reported a PCI system error on a component that resides in slot #. | Same as above. | Same as above. | Same as above. |
E1714 | Unknown Err | Low | BIOS has determined there has been an error in the system but is unable to determine its origin. | AC Cycle or SEL clear | Yes | POST, After POST |
E171F | PCIE Fatal Err B## D## F## | High | BIOS has reported a PCIe fatal error on a component that resides in PCI configuration space at bus ##, device ##, function ##. | AC Cycle or SEL clear | Yes | POST, After POST |
E171F | PCIE Fatal Slot # | High | BIOS has reported a PCIe fatal error on a component that resides in slot #. | Same as above. | Same as above. | Same as above. |
Hard Drives - Message Code: "x18xx" | ||||||
---|---|---|---|---|---|---|
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Phase When Event Can Occur? |
E1810 | HDD ## Fault | Low | Hard drive ## has had a fault as determined by the SAS subsystem. | AC Cycle or SEL clear | Yes | POST, After POST |
E1811 | HDD ##RbldAbrt | Low | Drive ## has had its rebuild aborted. | AC Cycle or SEL clear | Yes | POST, After POST |
E1812 | HDD ## Removed | Low | Drive ## has been removed from the system. | System reset or device is reseated/replaced/repaired. | Yes | POST, After POST |
Miscellaneous- Message Code: "x19xx" | ||||||
---|---|---|---|---|---|---|
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Phase When Event Can Occur? |
I1910 | Intrusion | Low | The chassis lid has been removed. | Chassis lid is returned to the system. | Yes | Any |
I1911 | >3ERRsChkLog | N/A | User must check the system event log (SEL) for the rest of the errors on the system .Thee LCD is limited to three error, warning, and/or informational messages at a time based on priority level. | Less than 3 events to display on the LCD. | No | Any |
I1912 | SEL Full | Med | System Event Log is full of events and because of this is unable to log anymore. You must clear the log in order for the Server Management controller to log any more events. | AC Cycle or SEL clear | Yes | Any |
E1913 | CPU & Firmware Mismatch | Med | Current version of BMC firmware is incompatible with the Woodcrest processor. | AC Cycle or SEL clear | Yes | POST |
BIOS Progress Codes - Message Code: N/A | ||||||
---|---|---|---|---|---|---|
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Phase When Event Can Occur? |
N/A | POWER | N/A | 0x01 -- System power-on. | N/A | No | Any |
N/A | MCODE | N/A | 0x02 -- CPU Microcode load. | N/A | No | Any |
N/A | CINIT | N/A | 0x03 -- Chipset Initialization. | N/A | No | Any |
N/A | MEMC | N/A | 0x04 -- Memory Configuration. | N/A | No | Any |
N/A | SBIOS | N/A | 0x05 -- BIOS shadow into memory. | N/A | No | Any |
N/A | PINIT | N/A | 0x06 -- Multiprocessor Initialization. | N/A | No | Any |
N/A | START | N/A | 0x07 -- POST processing start. | N/A | No | Any |
N/A | SMM | N/A | 0x08 -- System management interrupt (SMI) initialization. | N/A | No | Any |
N/A | PCIEN | N/A | 0x09 -- PCI Bus Enumeration & Video initialization. | N/A | No | Any |
N/A | VIDEO | N/A | 0x40 -- Display sign-on. | N/A | No | Any |
N/A | PCIC | N/A | 0x41 -- PCI Configuration. | N/A | No | Any |
N/A | OS | N/A | 0x7F -- Give control to OS. | N/A | No | Any |
N/A | E2010 | N/A | 0x80 -- No memory installed in the system. | N/A | No | Any |
N/A | E2011 | N/A | 0x81 -- Memory detected but is not configurable .Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket. | N/A | No | Any |
N/A | E2012 | N/A | 0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory. | N/A | No | Any |
N/A | E2013 | N/A | 0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory. | N/A | No | Any |
N/A | E2014 | N/A | 0x84 -- CMOS failure. CMOS'S RAM not working. | N/A | No | Any |
N/A | E1215 | N/A | 0x05 -- DMA controller failure. | N/A | No | Any |
N/A | E1116 | N/A | 0x80 -- Interrupt controller failure. | N/A | No | Any |
N/A | E1217 | N/A | 0x07 -- Timer refresh failure. | N/A | No | Any |
N/A | E1218 | N/A | 0x28 -- Programmable interval timer error. | N/A | No | Any |
N/A | E0119 | N/A | 0x29 -- Parity error. | N/A | No | Any |
N/A | E122A | N/A | 0x2a -- SIO failure. | N/A | No | Any |
N/A | E122B | N/A | 0x00b0 -- Keyboard controller failure. | N/A | No | Any |
N/A | E141C | N/A | 0x3c -- System management interrupt (SMI) initialization failure. | N/A | No | Any |
N/A | E.11 | N/A | 0xC4 -- BIOS shutdown test failure. | N/A | No | Any |
N/A | E.11 | N/A | 0xC4 -- BIOS POST memory test failure. Could be the result of bad memory. | N/A | No | Any |
N/A | E141F | N/A | 0xC4 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message. | N/A | No | Any |
N/A | E0000 | N/A | 0xC4 -- CPU configuration failure. Check screen for the actual error message. | N/A | No | Any |
N/A | E1221 | N/A | 0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the user guide. | N/A | No | Any |
N/A | E1222 | N/A | 22x -- General failure after video. Check screen for the actual error message. | N/A | No | Any |
BIOS Fatal Error Codes - Message Code: "x20xx" | ||||||
---|---|---|---|---|---|---|
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Phase When Event Can Occur? |
E2010 | No Memory | High | 0x80 -- No memory installed in the system. | System reset | Yes | POST |
E2011 | MemConfigErr | High | 0x81 -- Memory detected but is not configurable. Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket. | System reset | Yes | POST |
E2012 | Unusable Memory | High | 0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory. | System reset | Yes | POST |
E2013 | Shadow BIOS Fail | High | 0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory. | System reset | Yes | POST |
E2014 | CMOS Fail | High | 0x84 -- CMOS failure. CMOS'S RAM not working. | System reset | Yes | POST |
E2015 | DMA Controller | High | 0x85 -- DMA controller failure. | System reset | Yes | POST |
E2016 | IntController | High | 0x86 -- Interrupt controller failure. | System reset | Yes | POST |
E2017 | Timer Fail | High | 0x87 -- Timer refresh failure. | System reset | Yes | POST |
E2018 | ProgTimer | High | 0x88 -- Programmable interval timer error. | System reset | Yes | POST |
E2019 | Parity Error | High | 0x89 -- Parity error. | System reset | Yes | POST |
E201A | SIO Err | High | 0x8A -- SIO failure. | System reset | Yes | POST |
E201B | KybdController | High | 0x8B -- Keyboard controller failure. | System reset | Yes | POST |
E201C | SMI Init | High | 0x8C -- System management interrupt (SMI) initialization failure. | System reset | Yes | POST |
E201D | Shutdown Test | High | 0xC0 -- BIOS shutdown test failure. | System reset | Yes | POST |
E201E | POSTMemTest | High | 0xC1 -- BIOS POST memory test failure. Could be the result of bad memory. | System reset | Yes | POST |
E201F | DRACConfig | High | 0xC2 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message. | System reset | Yes | POST |
E2020 | CPUConfig | High | 0xC3 -- CPU configuration failure. Check screen for the actual error message. | System reset | Yes | POST |
E2021 | Memory Population | High | 0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the user guide. | System reset | Yes | POST |
E2022 | POST Fail | High | 0xFE -- General failure after video. Check screen for the actual error message. | System reset | Yes | POST |
Special Exceptions - Message Code: "x10xx" | ||||||
---|---|---|---|---|---|---|
Message Code | Message String | Message Priority | Message Comments | Minimum Action Required to Remove Message from LCD | Exists in SEL? | System Phase When Event Can Occur? |
E1000 | Failsafe, Call Support | Special | Check System Event Log for critical failure details. | AC Cycle or SEL clear | Yes | Any |
Dell 错误代码(供参考) 我试过报E1410 却是坏阵列卡 杯具相关推荐
- win7系统安装软件时出现错误代码800b0101 几个经验供参考
win7系统安装软件时出现错误代码800b0101 几个经验供参考 安装一个软件时出出如下问题 按以下方法尝试: 1.关闭杀毒软件,其它运行的软件,重新启动电脑,没用. 2.打开log file看,完 ...
- .NET平台下几种SOCKET模型的简要性能供参考
.NET平台下几种SOCKET模型的简要性能供参考 这个内容在cnblogs中也讨论过很多次了,这两天大概看了一些资料,看到一些简单的性能指标拿出来和大家讨论一下. Socket + Threads/ ...
- 高考志愿填报APP靠谱吗?大数据仅供参考不能依赖
6月24日,在众多考生的等待中,陕西2019年高考分数线公布.分数线公布后,对于考生和家长来说,最重要的事情就是填报高考志愿了.针对这种需求,一些指导高考志愿填报的APP应运而生.今天南京软件开发公司 ...
- 关于:请求中含有特殊字符,被禁止(已解决,可供参考)
页面直接报错: 请求中含有特殊字符,被禁止 以下总结下我遇到的问题:(供参考,以后遇到这种问题可以回来看看,开始我都一脸懵逼) 1.我的错误说明:点击保存数据直接页面报错了,显示请求中含有特殊字符,我 ...
- 如何攻破华信专业版保护卡v5.0.210706.3200,仅供参考
如何攻破华信专业版保护卡v5.0.210706.3200,仅供参考 声明 攻破流程 1 首先关闭ezdiskmonitor等程序 2 下载DiskGenius.傲梅分区助手来破坏并删除保护卡隐藏分区. ...
- 用大数据“填志愿”靠谱吗?专家:仅供参考不能依赖
从6月22日起,各省陆续公布了2019高考录取分数线,高考志愿填报的大幕也随之拉开. 如何填报志愿是摆在家长和考生面前的大事.目前,多家公司被这块市场吸引,纷纷推出大数据帮填志愿服务,甚至还有收费5万 ...
- python语言程序设计编程题_Python语言程序设计(2020年版)高等教育出版社,课后编程题答案(仅供参考)...
后面会补全,暂时只有部分,答案是自己写的,不是标准答案,仅供参考 习题三 1. .获得用户输入的一个整数,输出该整数百位及以上的数字 s=int(input("请输入大于或等于100的整数: ...
- 收发电子邮件属于计算机在方面的应用,计算机应用基础复习题(供参考).doc
计算机应用基础复习题(供参考) 计算机应用基础 1.计算机能够自动工作,主要是因为采用了(? ? ).A.二进制数制?? B.高速电子元件?? C.存储程序控制?? D.程序设计语言参考答案:C2.从 ...
- 如何有效防止DEDE织梦系统被挂木马安全设置(仅供参考)
尊敬的客户,您好! 感谢广大客户对我司工作的信任和支持! 我司在最近的一个多月内陆续发现多起因 DedeCMS 安全漏洞造成网站被上传恶意脚本的事件,入侵者可利用恶意脚本对外发送大量数据包,严重占用C ...
最新文章
- 京东员工因两年一毛钱没涨而离职,618后跳槽涨薪翻倍
- FPGA管脚分配文件的保存
- ListDefinition Tips
- MPICH 完整配置存档
- ionic + cordova 使用 cordova-gallery-api 获取本地相册所有图片
- fastapi 查询参数和字符串校验 / 路径参数和数值校验
- python大作业五子棋人人对战_五子棋总结(人人对战)
- UML类与类的关系, 总算理解了关联和依赖在实际中的区别
- 大华ITC215WEB相机常用功能设置说明
- Adobe软件的各种卸载工具和方法,不信灭不掉AE!
- 微信小程序swiper组件切换+个人资料展示
- 实验一 网络侦查与网络扫描
- vue cli 脚手架 重新安装步骤
- 使用UMI仿今日头条首页
- 美国电气与计算机工程专业排名,美国大学电气工程专业排名情况
- python背景图颜色_更改特定子图背景颜色(饼图外部)
- MayaToUE4之影视动画制作流程
- 泰勒公式求解极限(泰勒展不开)
- 物理思维在计算机中的应用,思维导图学物理 学会用大脑的语言进行思考
- 关于ECW文件格式读取