IBM P系列小型机更换电池步骤
1.查看电池信息
命令:smitty pxdam
选择“ Diagnostics and Recovery Options”
选择“Controller Rechargeable Battery Maintenance”
回车,可以看到电池信息
电池信息各参数含义如下:
battery state:显示电池当前具体状态,有以下几个可能的值
No battery warning/error:No warning or error condition currently exist 这种是电池的正常状态
Warning condition:A warning condition currently exists and an error has been logged 出现了一个警告并被记录在日志中
Error condition:An error condition currently exists and an error has been logged 电池已经出错
Unknow:Information is not available to determine whether a warning or error condition currently exists 无法判断
Power-on time(days):电池持续使用的天数
Adjusted power-on time(time):
Indicates the adjusted (prorated) power-on time, in units of days ,of the rechargeable Cache Battery Pack
Note:Some rechargeable Cache Battery Packs are negatively affected by higher temperatures and thus are prorated based on the amount of time that they spend at various ambient temperatures
Estimated(估算的) time to warning(days):
Estimated time, in units of days, until a message is issued indicating that the replacement fo the rechargeable Cache Bettery Pack should be scheduled
Estimated time to error(days):当值为0时,此时Cache被自动禁用,必须更换电池
Estimated time , in units of days ,until an error is reported indicating that the rechargeable Cache Bettery Pack must be replaced
Concurrently maintainable battery pack:该电池是否可以在线更换
Indicates that the rechargeable Cache Battery Pack can by replaced while the adapter continues to operate
Battery pack can be safely replaced:当值为YES时,该电池可以安全地更换,不会造成Cache数据丢失
Indicates that the adapter's write cache has been disabled and the rechargeable Cache Battery Pack can be safely replaced
2.强制将电池置为Error状态,使写Cache禁用,清空Cache内缓存的数据
命令:smittty pxdam
选择“Force Controller Rechargeable Battery Error”
最好再检查一次,电池信息中“Battery pack can be safely replaced”一项为YES
3.更换电池
注意:必须将旧电池拆下来至少15秒后,再安装新电池,否则PCI-X SCSI RAID卡将不能正常识别电池已更换。
注意:必须确保电池已处于Error状态,才能更换电池,以免Cache中缓存的数据丢失。
根据PCI-X SCSI RAID卡的不同类型,选择Concurrent方式或Non-Concurrent方式更换:
Non-Concurrent方式更换
更换电池必须将卡从机器中拔出
A Battery Pack Casing
B Cache Directory Card
Concurrent方式更换:
更换电池可以在线进行,只需单独将电池拔出,不需要把卡从机器中拔出
4.重新激活写Cache
smitty pxdam
5.清理黄灯告警
输入:diag 回车确认
FUNCTION SELECTION 801002
Move cursor to selection, then press Enter.
Diagnostic Routines
This selection will test the machine hardware. Wrap plugs and
other advanced functions will not be used.
Advanced Diagnostics Routines
This selection will test the machine hardware. Wrap plugs and
other advanced functions will be used.
Task Selection (Diagnostics, Advanced Diagnostics, Service Aids, etc.)
This selection will list the tasks supported by these procedures.
Once a task is selected, a resource menu may be presented showing
all resources supported by the task.
Resource Selection
This selection will list the resources in the system that are supported
by these procedures. Once a resource is selected, a task menu will
be presented showing all tasks that can be run on the resource(s).
选择“Task Selection (Diagnostics, Advanced Diagnostics, Service Aids, etc. )”
TASKS SELECTION LIST 801004
From the list below, select a task by moving the cursor to
the task and pressing 'Enter'.
To list the resources for the task highlighted, press 'List'.
[MORE...9]
Change Hardware Vital Product Data
Configure Reboot Policy
Delete Resource from Resource List
Disk Maintenance
Display Configuration and Resource List
Display Firmware Device Node Information
Display Hardware Error Report
Display Hardware Vital Product Data
Display Multipath I/O (MPIO) Device Configuration
Display Previous Diagnostic Results
Display Resource Attributes
Display Service Hints
Display Software Product Data
Display USB Devices
Display or Change Bootlist
Format Media
Gather System Information
Hot Plug Task
Identify and Attention Indicators
Load ISO Image to USB Mass Storage Device
Local Area Network Analyzer
Log Repair Action
Microcode Tasks
RAID Array Manager
Update Disk Based Diagnostics
Update and Manage System Flash
找到“Log Repair Action”,回车
LOG REPAIR ACTION 801016
Select a resource if it has been replaced recently or has had
corrective actions performed against it. This will update the error
log to prevent diagnostics from performing Error Log Analysis on the
obsolete error log entries for the resource.
To select a resource, move the cursor to the resource and press 'Enter'.
To cancel the selection, press 'Enter' again.
Once all selections have been made, press 'Commit'.
To avoid selecting a resource, press 'Previous Menu'.
sys0 System Object
sysplanar0 System Planar
U787A.001.DPM18T9-
sisscsia0 P1 PCI-X Dual Channel Ultra320 SCSI Adapter
scsi0 P1-T10 PCI-X Dual Channel Ultra320 SCSI Adapter
bus
hdisk0 P1-T10-L3-L0 16 Bit LVD SCSI Disk Drive (300000 MB)
hdisk17 P1-T10-L8-L0 16 Bit LVD SCSI Disk Drive (73400 MB)
ses0 P1-T10-L15-L0 SCSI Enclosure Services Device
scsi1 P1-T11 PCI-X Dual Channel Ultra320 SCSI Adapter
bus
选择“sys0”,回车确认
To select a resource, move the cursor to the resource and press 'Enter'.
To cancel the selection, press 'Enter' again.
Once all selections have been made, press 'Commit'.
To avoid selecting a resource, press 'Previous Menu'.
+ sys0 System Object
sysplanar0 System Planar
U787A.001.DPM18T9-
sisscsia0 P1 PCI-X Dual Channel Ultra320 SCSI Adapter
scsi0 P1-T10 PCI-X Dual Channel Ultra320 SCSI Adapter
bus
hdisk0 P1-T10-L3-L0 16 Bit LVD SCSI Disk Drive (300000 MB)
hdisk17 P1-T10-L8-L0 16 Bit LVD SCSI Disk Drive (73400 MB)
ses0 P1-T10-L15-L0 SCSI Enclosure Services Device
scsi1 P1-T11 PCI-X Dual Channel Ultra320 SCSI Adapter
bus
usbhc2 P1 USB Enhanced Host Controller (3310e000)
usbhc0 P1 USB Host Controller (33103500)
usbhc1 P1 USB Host Controller (33103500)
ent0 P1-T5 2-Port 10/100/1000 Base-TX PCI-X Adapter
(14108902)
ent1 P1-T6 2-Port 10/100/1000 Base-TX PCI-X Adapter
(14108902)
fcs0 P1-C4-T1 FC Adapter
fscsi0 P1-C4-T1 FC SCSI I/O Controller Protocol Device
L2cache0 L2 Cache
mem0 Memory
oppanel Operator panel
F1=Help F4=List F7=Commit Esc+0=Exit
F3=Previous Menu
此时,sys0前面出现了一个“+”符号,表示已选中该项
按F7(或ESC+7)提交确认
ESC+0退出
告警清除!
IBM P系列小型机更换电池步骤相关推荐
- v7000更换电池步骤_ups电源运行中是否可以更换电池?应如何操作呢
ups电源在日常使用中除了日常维护工作之外,对于使用达到一定年限的时候,内部使用的ups蓄电池就需要更换了,很多人以为ups不间段电源在工作的时候是可以跟换电池.其实,这个具体就需要看ups电源设计的 ...
- v7000更换电池步骤_IBM V系列存储维护
v系列存储 硬件型虚拟化存储 1.v7000 机头24块硬盘 两边电源中间上下两个控制器 与传统存储类似架构 service ip 管理ip每个控制器两以太网管理网口默认ip为:192.168.70. ...
- ibm服务器p系列小型机,IBM Power系列小型机发展历史
Power System服务器 AIX RISC/CISC SMT QCM SP Hypervisor LPAR (Performance Optimization With Enhanced RI ...
- v7000更换电池步骤_v7000 gen1 电池更换问题
已经更换两次电池了.v7000 code 是6.4.1 故障现象:11月23日的日志,PSU 1 上面的电池报错EOF,日志如下:决定更换电池 battery_id:1 status:online c ...
- v7000更换电池步骤_UPS电池更换方案
为了使机房内机柜设备在不断电的情况下更换蓄电池, 并且避免在更换 电池的过程中出现问题,首先应由专业的 UPS 技术工程师进行更换电池组, 同时在更换电池组之前应对机房现场情况进行勘察,特别是对 UP ...
- IBM p系列小型机日常维护及故障排除时常用命令(检查IBM设备状态汇总)
1. 确认所在主机及系统版本 通过#hostname.#oslevel确认所在主机后,再进行后续操作 2.运行lsdev 命令配置各种参数,所列各种设备状态都应为Available. #lsdev – ...
- v7000更换电池步骤_[原创]IBM V7000 SVC更换已经告警的UPS电池详细步骤
共73 条记录, 每页显示 50 条, 页签: [1] [2] 标题:[原创]IBM V7000 SVC更换已经告警的UPS电池详细步骤 1楼 admin 发表于:2017-11-9 13:37:32 ...
- IBM power小型机更换硬盘步骤
更换硬盘的步骤: (1)检查磁盘情况,确定损坏的硬盘,确定VG,PV,LV之间的对应关系 查看errpt确定hdisk5报错 #lspv –l hdisk5 //查看PV上的lv的情况,共有两个LV: ...
- 日常检查IBM P系列小型机状态的项目及其相关命令
1 运行lsdev 命令配以各种参数,所列各种小型机设备状态都应为Available. #lsdev –C –H –S a 列出小型机系统中可用设备. #lsdev –Cc process ...
最新文章
- R语言with函数和within函数:with函数基于表达式在dataframe上计算、within函数基于表达式在dataframe上计算并修改原始数据
- 数字图像处理4:图像的像素级运算
- 20165315 第八周考试课下补做
- python下载m3u8地址_python 下载m3u8视频的示例代码
- spring boot 邮件端口_不会吧,SpringBoot还能发送邮件发送邮件?快来看看如何操作吧
- Nginx调度器(反向代理)
- CSS精粹之布局技巧
- mysql 左表为null_sql left join count 左表为空表的时候出现空行
- c#windfrom打包_WinForm程序打包教程
- 谷歌浏览器如何截全屏长图,超级方便实用
- python爬取豆瓣电影并分析_Python爬虫入门 | 2 爬取豆瓣电影信息
- MDI Jade6的安装(含ocx控件的安装、PDF索引建立、修改注册表)
- 【软件工具】之 TotalCommander
- 微信屏蔽网址解决办法 如何恢复微信访问拦截 微信网页拦截怎么办
- 液晶显示器偏光膜的基本原理
- 技术之路如何成长而不迷茫
- java实现html页面转pdf解决方案_[Java教程]纯js实现html转pdf
- 10月25日lol服务器维护,《LOL》维护到几点10月25日 英雄联盟10.25维护到几点结束...
- 伪原创视频的处理技巧
- linux停止正在执行脚本