jbod ugood 磁盘驱动状态_LSI Storcli 工具使用
使用实例
#查询RAID卡的详细信息。
[root@localhost ~]# ./storcli64 /c0 show
Generating detailed summary of the adapter, it may take a while to complete.
CLI Version = 007.0409.0000.0000 Nov 06, 2017
Operating system = Linux3.10.0-514.el7.x86_64
Controller = 0
Status = Success
Description = None
Product Name = SAS3108
Serial Number =
SAS Address = 50030130f0900000
PCI Address = 00:01:00:00
System Time = 07/07/2018 22:06:42
Mfg. Date = 00/00/00
Controller Time = 07/07/2018 14:06:41
FW Package Build = 24.16.0-0093
BIOS Version = 6.32.02.0_4.17.08.00_0x06150500
FW Version = 4.660.00-8140
Driver Name = megaraid_sas
Driver Version = 06.811.02.00-rh1
Current Personality = RAID-Mode
Vendor Id = 0x1000
Device Id = 0x5D
SubVendor Id = 0x19E5
SubDevice Id = 0xD207
Host Interface = PCI-E
Device Interface = SAS-12G
Bus Number = 1
Device Number = 0
Function Number = 0
Drive Groups = 1
TOPOLOGY :
========
-----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
-----------------------------------------------------------------------------
0 - - - - RAID1 Optl N 744.125 GB dflt N N none N N
0 0 - - - RAID1 Optl N 744.125 GB dflt N N none N N
0 0 0 252:1 18 DRIVE Onln N 744.125 GB dflt N N none - N
0 0 1 252:0 48 DRIVE Onln N 744.125 GB dflt N N none - N
-----------------------------------------------------------------------------
DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready
Virtual Drives = 1
VD LIST :
=======
---------------------------------------------------------------
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
---------------------------------------------------------------
0/0 RAID1 Optl RW Yes RWBD - ON 744.125 GB
---------------------------------------------------------------
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
Physical Drives = 6
PD LIST :
=======
---------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
---------------------------------------------------------------------------------
252:0 48 Onln 0 744.125 GB SATA SSD N N 512B INTEL SSDSC2BB800G4 U -
252:1 18 Onln 0 744.125 GB SATA SSD N N 512B INTEL SSDSC2BB800G4 U -
252:2 19 UGood - 744.125 GB SATA SSD N N 512B INTEL SSDSC2BA800G4 U -
252:3 20 UGood - 744.125 GB SATA SSD N N 512B INTEL SSDSC2BA800G4 U -
252:4 49 UGood - 744.125 GB SATA SSD N N 512B INTEL SSDSC2BB800G4 U -
252:5 47 UGood - 744.125 GB SATA SSD N N 512B INTEL SSDSC2BB800G4 U -
---------------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
Cachevault_Info :
===============
------------------------------------
Model State Temp Mode MfgDate
------------------------------------
CVPM02 Optimal 28C - 2016/11/04
------------------------------------
#查询slot0的物理硬盘的信息。
[root@localhost ~]# ./storcli64 /c0/e252/s0 show all
CLI Version = 007.0409.0000.0000 Nov 06, 2017
Operating system = Linux3.10.0-514.el7.x86_64
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.
Drive /c0/e252/s0 :
=================
---------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
---------------------------------------------------------------------------------
252:0 48 Onln 0 744.125 GB SATA SSD N N 512B INTEL SSDSC2BB800G4 U -
---------------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
Drive /c0/e252/s0 - Detailed Information :
========================================
Drive /c0/e252/s0 State :
=======================
Shield Counter = 0
Media Error Count = 0
Other Error Count = 0
Drive Temperature = 20C (68.00 F)
Predictive Failure Count = 0
S.M.A.R.T alert flagged by drive = No
Drive /c0/e252/s0 Device attributes :
===================================
SN = PHWL517601YR800RGN
Manufacturer Id = ATA
Model Number = INTEL SSDSC2BB800G4
NAND Vendor = NA
WWN = 55cd2e404c533246
Firmware Revision = D2010370
Raw size = 745.211 GB [0x5d26ceb0 Sectors]
Coerced size = 744.125 GB [0x5d040800 Sectors]
Non Coerced size = 744.711 GB [0x5d16ceb0 Sectors]
Device Speed = 6.0Gb/s
Link Speed = 6.0Gb/s
NCQ setting = Enabled
Write cache = N/A
Logical Sector Size = 512B
Physical Sector Size = 4 KB
Connector Name = Port A x1
Drive /c0/e252/s0 Policies/Settings :
===================================
Drive position = DriveGroup:0, Span:0, Row:1
Enclosure position = 1
Connected Port Number = 0(path0)
Sequence Number = 2
Commissioned Spare = No
Emergency Spare = No
Last Predictive Failure Event Sequence Number = 0
Successful diagnostics completion on = N/A
SED Capable = No
SED Enabled = No
Secured = No
Cryptographic Erase Capable = No
Locked = No
Needs EKM Attention = No
PI Eligible = No
Certified = No
Wide Port Capable = No
Port Information :
================
-----------------------------------------
Port Status Linkspeed SAS address
-----------------------------------------
0 Active 6.0Gb/s 0x4433221100000000
-----------------------------------------
Inquiry Data =
40 00 ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00
00 00 00 00 48 50 4c 57 31 35 36 37 31 30 52 59
30 38 52 30 4e 47 20 20 00 00 00 00 00 00 32 44
31 30 33 30 30 37 4e 49 45 54 20 4c 53 53 53 44
32 43 42 42 30 38 47 30 20 34 20 20 20 20 20 20
20 20 20 20 20 20 20 20 20 20 20 20 20 20 01 80
00 40 00 2f 00 40 00 00 00 00 07 00 ff 3f 10 00
3f 00 10 fc fb 00 01 bf ff ff ff 0f 00 00 07 00
# 查询VD 0的信息。
[root@rhel6u5 ~]# /opt/MegaRAID/storcli/storcli64 /c0/v0 show all
Controller = 0
Status = Success
Description = None
/c0/v0 :
======
---------------------------------------------------------
DG/VD TYPE State Access Consist Cache sCC Size Name
---------------------------------------------------------
1/0 RAID1 Optl RW Yes RWTD - 1.089 TB
---------------------------------------------------------
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|
R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
PDs for VD 0 :
============
-----------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
-----------------------------------------------------------------------
25:22 14 Onln 1 1.089 TB SAS HDD N N 512B ST1200MM0007 U
25:23 26 Onln 1 1.089 TB SAS HDD N N 512B ST1200MM0007 U
-----------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded
VD0 Properties :
==============
Strip Size = 256 KB
Number of Blocks = 2341795840
VD has Emulated PD = No
Span Depth = 1
Number of Drives Per Span = 2
Write Cache(initial setting) = WriteThrough
Disk Cache Policy = Disk's Default
Encryption = None
Data Protection = Disabled
Active Operations = None
Exposed to OS = Yes
Creation Date = 04-01-2018
Creation Time = 12:38:35 PM
Emulation type = None
jbod ugood 磁盘驱动状态_LSI Storcli 工具使用相关推荐
- jbod ugood 磁盘驱动状态_storcli64和smartctl定位硬盘的故障信息
定位硬盘盘位和盘符的方法 From Lin.Wang Section One : Introduction strocli是megacli的升级版本,针对于戴尔服务器是perccli,用法完全一致 s ...
- jbod ugood 磁盘驱动状态_AS SSD Benchmark查看硬盘状态的详细操作步骤
最近很多朋友咨询关于AS SSD Benchmark怎么查看硬盘状态的问题,今天的这篇教程就来聊一聊这个话题,希望可以帮助到有需要的朋友. AS SSD Benchmark查看硬盘状态的详细操作步骤 ...
- jbod ugood 磁盘驱动状态_NTFS磁盘读写工具Mounty免费版
mounty for mac版是Mac OS平台上的一款ntfs格式读写工具,软件虽小但功能实用,其主要功能类似paragon ntfs for mac.当你插入 ntfs 硬盘后会提示是否创新加载成 ...
- jbod ugood 磁盘驱动状态_Win10扫描修复磁盘驱动器错误全攻略
如果你的电脑在磁盘读写的过程中总是出现莫名的错误,或者是电脑开机时总是提示"正在扫描和修复驱动器",那么就说明你的电脑磁盘的文件系统出现错误了,需要进行扫描与修复.下面艾薇百科就来 ...
- jbod ugood 磁盘驱动状态_英特尔脱坑玩家必看:AMD主板RAID设置介绍
原标题:英特尔脱坑玩家必看:AMD主板RAID设置介绍 之前看到一则笑话说二战时期的日本陆军与海军竞争,陆军螺丝往左拧,海军螺丝就必须要设计成往右拧.作为CPU界的一对老冤家,AMD和英特尔使用同样的 ...
- jbod ugood 磁盘驱动状态_组成原理—磁盘/IO/中断
1.外存储器: 计算机的外存储器又称为辅助存储器,目前主要使用磁表面存储器. 原理:当磁头和磁介质有相对运动, 通过电磁转换完成读写操作.串行工作模式,每度一位,磁头都要移动. 磁盘存储器: 存储区域 ...
- jbod ugood 磁盘驱动状态_如何检查Mac磁盘空间,mac磁盘空间其他怎么清理
致力于成为您终身的苹果管家 点击上方蓝字 关注我们 检查Mac磁盘空间的时候,你会发现"其他存储"占用了驱动器太多的空间.你知道Mac上的其他存储在哪里,mac磁盘空间其他怎么清 ...
- 优缺点 快速扫描 硬盘监测_有了这6款mac硬盘检测工具 你就能够快速检测磁盘的状态和错误情况...
在电脑硬件中,硬盘算是比较脆弱的硬件之一,但又是最重要的硬件之一,因其存储着电脑所有重要数据,因此需要定期检测,以免丢失数据,所以检测工具就得选比较可靠的,有了这6款mac硬盘检测工具,你就能够快速检 ...
- Linux使用storcli工具查看服务器硬盘和raid组信息
1.简介 MegaCli 是LSI公司官方提供的SCSI卡管理工具,由于LSI被收购变成了现在的Broadcom,所以现在想下载MegaCli, 需要去Broadcom官网查找Legacy产品支持,搜 ...
最新文章
- After paper reading.......
- 【leetcode】147. Insertion Sort List
- Vue解析--如何应对面试官提问
- 单链表的读取、插入与删除
- 连通性问题--Algorithms IN C读书笔记
- HCIE-Security Day9:5个实验理解NAT Server
- 在 Mac OS X 安装gcc编辑环境,make不能用时参考
- 闲置eSATA接口影响Windows7启动速度案例分析
- linux怎么cat结果导出txt,cat 输出文件内容
- UI界面设计相关知识(一)
- 阿里网盘官网网页,怎么隐藏的这么深
- Markdown语法介绍(详细)
- Linux服务之DHCP服务篇(scp)
- SwiftUI——全局背景渐变色(Gradient)案例
- 运用Share.js插件在网页上添加一键分享到微博、微信等
- 阿里云国际版如何使用NGINX作为HTTPS转发代理服务器
- 服务启动时,报Command line is too long异常
- [转载]JS和AS交互 作者:ludanlove
- 如何用matlab实现小波变换
- 做一个墨水屏电子钟,炫酷!
热门文章
- 交换技术及其具体应用
- sublime text 3中安装ctags支持函数跳转,安装convertToUtf8支持中文步骤[工具篇]
- Android 组件系列-----Activity生命周期
- SCOM 2012知识分享-17:创建并管理组
- 移动应用的黄金四分类
- 8086汇编语言显示一串字符串中ASCII码最大的一个字符
- 0 full gc时cpu idle_结合GC日志讲讲CMS垃圾收集器
- 学业水平考试b能上985吗_这是最好考的985高校,如今被“降级”到双一流B类,真让人惋惜...
- 编写测试用例的实用小技巧
- html新标准,HTML 5新标准将会在2022年正式发布