硬件系统重点关注的指标:

# 总核数 = 物理CPU个数 X 每颗物理CPU的核数
# 总逻辑CPU数 = 物理CPU个数 X 每颗物理CPU的核数 X 超线程数# 查看物理CPU个数
cat /proc/cpuinfo| grep "physical id"| sort| uniq| wc -l
或grep 'physical id' /proc/cpuinfo | sort -u | wc -l# 查看每个物理CPU中core的个数(即核数)
cat /proc/cpuinfo| grep "cpu cores"| uniq
或者grep 'core id' /proc/cpuinfo | sort -u | wc -l# 查看逻辑CPU的个数
cat /proc/cpuinfo| grep "processor"| wc -l
或者grep 'processor' /proc/cpuinfo | sort -u | wc -l
# 查看CPU信息(型号)
cat /proc/cpuinfo | grep name | cut -f2 -d: | uniq -c
或者dmidecode -s processor-version
#查看内 存信息
cat /proc/meminfo

1.查看硬件服务器型号:

# dmidecode|grep "System Information" -A9|egrep  "Manufacturer|Product"
Manufacturer: HP
Product Name: ProLiant DL380 Gen9

2.查看操作系统信息:

2.1 发行版本信息

# cat /etc/redhat-release
CentOS Linux release 7.2.1511 (Core)
# cat /etc/issue
CentOS release 7.1
Kernel \r on an \m#yum install -y redhat-lsb
#lsb_release -a
LSB Version:    :core-4.1-amd64:core-4.1-noarch:cxx-4.1-amd64:cxx-4.1-noarch:desktop-4.1-amd64:desktop-4.1-noarch:languages-4.1-amd64:languages-4.1-noarch:printing-4.1-amd64:printing-4.1-noarch
Distributor ID: CentOS
Description:    CentOS Linux release 7.4.1708 (Core)
Release:        7.4.1708
Codename:       Core

2.2查看操作系统是否是64bit:
# getconf LONG_BIT
64

2.3  查看内核版本信息:

# uname -a
Linux node1 3.10.0-327.el7.x86_64 #1 SMP Thu Nov 19 22:10:57 UTC 2015 x86_64 x86_64 x86_64 GNU/Linux

2.4 查看系统已经加载的模块:

# lsmod
Module                  Size  Used by
dccp_diag              12596  0
dccp                   93080  1 dccp_diag
tcp_diag               12591  0
udp_diag               12801  0
inet_diag              18543  3 tcp_diag,dccp_diag,udp_diag
unix_diag              12601  0
rbd                    73158  0
ip6table_nat           12864  0
nf_conntrack_ipv6      18738  1
nf_defrag_ipv6         34768  1 nf_conntrack_ipv6
nf_nat_ipv6            14131  1 ip6table_nat
ip6_tables             27025  1 ip6table_nat
ipt_REJECT             12541  0
veth                   13365  0
xt_ipvs                12616  1
xt_set                 13181  2
xt_multiport           12798  35
iptable_mangle         12695  1
iptable_raw            12678  1
ip_set_hash_net        31664  2
nf_conntrack_netlink    36150  0
xt_statistic           12601  2
xt_nat                 12681  15
xt_recent              18542  2
ip_set                 36439  2 ip_set_hash_net,xt_set
nfnetlink              14606  2 ip_set,nf_conntrack_netlink
ip_vs                 140944  1 xt_ipvs
xt_comment             12504  219
xt_mark                12563  38
ipt_MASQUERADE         12678  3
nf_nat_masquerade_ipv4    13412  1 ipt_MASQUERADE
iptable_nat            12875  1
nf_conntrack_ipv4      14862  13
nf_defrag_ipv4         12729  1 nf_conntrack_ipv4
nf_nat_ipv4            14115  1 iptable_nat
xt_addrtype            12635  3
iptable_filter         12810  1
xt_conntrack           12760  12
nf_nat                 26146  4 nf_nat_ipv4,nf_nat_ipv6,xt_nat,nf_nat_masquerade_ipv4
nf_conntrack          105745  9 ip_vs,nf_nat,nf_nat_ipv4,nf_nat_ipv6,xt_conntrack,nf_nat_masquerade_ipv4,nf_conntrack_netlink,nf_conntrack_ipv4,nf_conntrack_ipv6
bridge                119562  0
stp                    12976  1 bridge
llc                    14552  2 stp,bridge
overlay                42451  11
ceph                  305045  0
libceph               244999  2 rbd,ceph
dns_resolver           13140  1 libceph
iTCO_wdt               13480  0
iTCO_vendor_support    13718  1 iTCO_wdt
intel_powerclamp       18648  0
coretemp               13435  0
intel_rapl             18773  0
kvm_intel             162153  0
kvm                   525259  1 kvm_intel
crc32_pclmul           13113  0
ghash_clmulni_intel    13259  0
aesni_intel            69884  0
lrw                    13286  1 aesni_intel
gf128mul               14951  1 lrw
glue_helper            13990  1 aesni_intel
ablk_helper            13597  1 aesni_intel
cryptd                 20359  3 ghash_clmulni_intel,aesni_intel,ablk_helper
ipmi_ssif              23695  0
pcspkr                 12718  0
sb_edac                27005  0
edac_core              57922  1 sb_edac
lpc_ich                21073  0
i2c_i801               18134  0
mfd_core               13435  1 lpc_ich
sg                     40721  0
hpilo                  17381  0
hpwdt                  14242  0
shpchp                 37032  0
wmi                    19070  0
ipmi_si                53524  0
ipmi_msghandler        46609  2 ipmi_ssif,ipmi_si
pcc_cpufreq            14082  0
acpi_power_meter       18087  0
ip_tables              27240  4 iptable_filter,iptable_mangle,iptable_nat,iptable_raw
xfs                   939662  2
libcrc32c              12644  3 xfs,ip_vs,libceph
sd_mod                 45497  3
crc_t10dif             12714  1 sd_mod
crct10dif_generic      12647  0
crct10dif_pclmul       14289  1
crct10dif_common       12595  3 crct10dif_pclmul,crct10dif_generic,crc_t10dif
crc32c_intel           22079  1
mgag200                41467  1
serio_raw              13462  0
syscopyarea            12529  1 mgag200
sysfillrect            12701  1 mgag200
sysimgblt              12640  1 mgag200
drm_kms_helper        125008  1 mgag200
ttm                    93441  1 mgag200
ixgbe                 263239  0
igb                   192596  0
drm                   349210  4 ttm,drm_kms_helper,mgag200
tg3                   170699  0
mdio                   13807  1 ixgbe
dca                    15130  2 igb,ixgbe
i2c_algo_bit           13413  2 igb,mgag200
ptp                    19231  3 igb,tg3,ixgbe
i2c_core               40582  7 drm,igb,i2c_i801,ipmi_ssif,drm_kms_helper,mgag200,i2c_algo_bit
hpsa                   90197  2
pps_core               19106  1 ptp

3.查看服务器CPU统计信息:

# lscpu
Architecture:          x86_64
CPU op-mode(s):        32-bit, 64-bit
Byte Order:            Little Endian
CPU(s):                48
On-line CPU(s) list:   0-47
Thread(s) per core:    2
Core(s) per socket:    12
Socket(s):             2
NUMA node(s):          2
Vendor ID:             GenuineIntel
CPU family:            6
Model:                 79
Model name:            Intel(R) Xeon(R) CPU E5-2650 v4 @ 2.20GHz
Stepping:              1
CPU MHz:               1200.000
BogoMIPS:              4433.40
Virtualization:        VT-x
L1d cache:             32K
L1i cache:             32K
L2 cache:              256K
L3 cache:              30720K
NUMA node0 CPU(s):     0-11,24-35
NUMA node1 CPU(s):     12-23,36-47# cat /proc/cpuinfo
....
processor: 47
vendor_id: GenuineIntel
cpu family: 6
model: 79
model name: Intel(R) Xeon(R) CPU E5-2650 v4 @ 2.20GHz
stepping: 1
microcode: 0xb00002a
cpu MHz: 1200.000
cache size: 30720 KB
physical id: 1
siblings: 24
core id: 13
cpu cores: 12
apicid: 59
initial apicid: 59
fpu: yes
fpu_exception: yes
cpuid level: 20
wp: yes
flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx pdpe1gb rdtscp lm constant_tsc arch_perfmon pebs bts rep_good nopl xtopology nonstop_tsc aperfmperf eagerfpu pni pclmulqdq dtes64 monitor ds_cpl vmx smx est tm2 ssse3 fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt tsc_deadline_timer aes xsave avx f16c rdrand lahf_lm abm 3dnowprefetch ida arat epb pln pts dtherm tpr_shadow vnmi flexpriority ept vpid fsgsbase tsc_adjust bmi1 hle avx2 smep bmi2 erms invpcid rtm cqm rdseed adx smap xsaveopt cqm_llc cqm_occup_llc
bogomips: 4433.40
clflush size: 64
cache_alignment: 64
address sizes: 46 bits physical, 48 bits virtual
power management:

4.查看CPU型号、插槽数(物理CPU个数)、内核数(cores)、逻辑CPU个数:

# cat /proc/cpuinfo | grep name | cut -f2 -d: | uniq -c48  Intel(R) Xeon(R) CPU E5-2650 v4 @ 2.20GHz
# cat /proc/cpuinfo| grep "physical id"| sort| uniq| wc -l
2
# cat /proc/cpuinfo| grep "cpu cores"| uniq
cpu cores: 12
# cat /proc/cpuinfo| grep "processor"| wc -l
48
理论上不使用超线程技术的前提下有如下结论:物理CPU个数*核数=逻辑CPU个数
配置服务器的应用时,以逻辑CPU个数为准。

5.内存信息查看:
查看服务器内存使用的情况:

# free -htotal        used        free      shared  buff/cache   available
Mem:           188G         20G         40G         21M        127G        167G
Swap:            0B          0B          0Btotal: 内存总量
used: 已使用
free: 未使用
shared: 多进程共享的内存总量
-buffers/cache: 已使用内存
+buffers/cache: 可用内存
可用内存=free+buffers+cached内存硬件信息:
# dmidecode -t memory
...
Handle 0x0023, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x000B
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: 23
Locator: PROC 2 DIMM 12
Bank Locator: Not Specified
Type: DDR4
Type Detail: Synchronous Registered (Buffered)
Speed: 2400 MHz
Manufacturer: HP
Serial Number: Not Specified
Asset Tag: Not Specified
Part Number: 809083-091
Rank: 2
Configured Clock Speed: 2400 MHz
Minimum Voltage:  1.2 V
Maximum Voltage:  1.2 V
Configured Voltage:  1.2 V查看内存详细使用情况:
# cat /proc/meminfo
MemTotal:       197965372 kB
MemFree:        42671988 kB
MemAvailable:   175652544 kB
Buffers:             876 kB
Cached:         129411972 kB
SwapCached:            0 kB
Active:         56358672 kB
Inactive:       93131072 kB
Active(anon):   20078472 kB
Inactive(anon):    20284 kB
Active(file):   36280200 kB
Inactive(file): 93110788 kB
Unevictable:           0 kB
Mlocked:               0 kB
SwapTotal:             0 kB
SwapFree:              0 kB
Dirty:                28 kB
Writeback:             0 kB
AnonPages:      20079652 kB
Mapped:           322976 kB
Shmem:             21852 kB
Slab:            4258000 kB
SReclaimable:    3927428 kB
SUnreclaim:       330572 kB
KernelStack:       25648 kB
PageTables:        48100 kB
NFS_Unstable:          0 kB
Bounce:                0 kB
WritebackTmp:          0 kB
CommitLimit:    98982684 kB
Committed_AS:   23618788 kB
VmallocTotal:   34359738367 kB
VmallocUsed:      702024 kB
VmallocChunk:   34258194444 kB
HardwareCorrupted:     0 kB
AnonHugePages:  19802112 kB
HugePages_Total:       0
HugePages_Free:        0
HugePages_Rsvd:        0
HugePages_Surp:        0
Hugepagesize:       2048 kB
DirectMap4k:      248576 kB
DirectMap2M:    19546112 kB
DirectMap1G:    183500800 kB查看内存的插槽数,已经使用多少插槽.每条内存多大:
# dmidecode|grep -A5 "Memory Device"|grep Size|grep -v Range
Size: 32 GB
Size: No Module Installed
Size: No Module Installed
Size: No Module Installed
Size: No Module Installed
Size: No Module Installed
Size: No Module Installed
Size: No Module Installed
Size: 32 GB
Size: No Module Installed
Size: No Module Installed
Size: 32 GB
Size: 32 GB
Size: No Module Installed
Size: No Module Installed
Size: No Module Installed
Size: No Module Installed
Size: No Module Installed
Size: No Module Installed
Size: No Module Installed
Size: 32 GB
Size: No Module Installed
Size: No Module Installed
Size: 32 GB

6.硬盘:
查看硬盘和分区分布

# lsblk
NAME   MAJ:MIN RM   SIZE RO TYPE MOUNTPOINT
sda      8:0    0 931.5G  0 disk
└─sda1   8:1    0 931.5G  0 part /
sdb      8:16   0   2.2T  0 disk /data

查看硬盘和分区的详细信息:

# fdisk -lDisk /dev/sda: 1000.2 GB, 1000171331584 bytes, 1953459632 sectors
Units = sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 262144 bytes / 262144 bytes
Disk label type: dos
Disk identifier: 0x0008f54aDevice Boot      Start         End      Blocks   Id  System
/dev/sda1            2048  1953458175   976728064   83  LinuxDisk /dev/sdb: 2400.3 GB, 2400348626944 bytes, 4688180912 sectors
Units = sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 4096 bytes
I/O size (minimum/optimal): 262144 bytes / 1310720 bytes

查看文件系统的磁盘空间占用情况:

# df -h
Filesystem      Size  Used Avail Use% Mounted on
/dev/sda1       932G  178G  754G  20% /
devtmpfs         95G     0   95G   0% /dev
tmpfs            95G     0   95G   0% /dev/shm
tmpfs            95G   18M   95G   1% /run
tmpfs            95G     0   95G   0% /sys/fs/cgroup
/dev/sdb        2.2T   24G  2.2T   2% /data
tmpfs            19G     0   19G   0% /run/user/0

7.查看物理网卡的信息:

# lspci | grep -i 'eth'
02:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5719 Gigabit Ethernet PCIe (rev 01)
02:00.1 Ethernet controller: Broadcom Corporation NetXtreme BCM5719 Gigabit Ethernet PCIe (rev 01)
02:00.2 Ethernet controller: Broadcom Corporation NetXtreme BCM5719 Gigabit Ethernet PCIe (rev 01)
02:00.3 Ethernet controller: Broadcom Corporation NetXtreme BCM5719 Gigabit Ethernet PCIe (rev 01)
04:00.0 Ethernet controller: Intel Corporation 82599ES 10-Gigabit SFI/SFP+ Network Connection (rev 01)
04:00.1 Ethernet controller: Intel Corporation 82599ES 10-Gigabit SFI/SFP+ Network Connection (rev 01)
08:00.0 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01)
08:00.1 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01)

8.NVIDIA显卡查看:

# nvidia-smi
+-----------------------------------------------------------------------------+
| NVIDIA-SMI 375.26                 Driver Version: 375.26                    |
|-------------------------------+----------------------+----------------------+
| GPU  Name        Persistence-M| Bus-Id        Disp.A | Volatile Uncorr. ECC |
| Fan  Temp  Perf  Pwr:Usage/Cap|         Memory-Usage | GPU-Util  Compute M. |
|===============================+======================+======================|
|   0  Tesla K80           Off  | 0000:04:00.0     Off |                    0 |
| N/A   60C    P0    75W / 149W |   4344MiB / 11439MiB |      2%      Default |
+-------------------------------+----------------------+----------------------+
|   1  Tesla K80           Off  | 0000:05:00.0     Off |                    0 |
| N/A   43C    P0    89W / 149W |   2196MiB / 11439MiB |     15%      Default |
+-------------------------------+----------------------+----------------------+
|   2  Tesla K80           Off  | 0000:08:00.0     Off |                    0 |
| N/A   90C    P0   100W / 149W |   2196MiB / 11439MiB |     98%      Default |
+-------------------------------+----------------------+----------------------+
|   3  Tesla K80           Off  | 0000:09:00.0     Off |                    0 |
| N/A   60C    P0    87W / 149W |   4212MiB / 11439MiB |     26%      Default |
+-------------------------------+----------------------+----------------------++-----------------------------------------------------------------------------+
| Processes:                                                       GPU Memory |
|  GPU       PID  Type  Process name                               Usage      |
|=============================================================================|
|    0     25459    C   python3                                       4336MiB |
|    1     25459    C   python3                                       2188MiB |
|    2     25459    C   python3                                       2188MiB |
|    3     25459    C   python3                                       4204MiB |
+-----------------------------------------------------------------------------+
WARNING: infoROM is corrupted at gpu 0000:04:00.0

9.其他PCI插卡设备的信息:

# lspci
00:00.0 Host bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DMI2 (rev 01)
00:01.0 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 1 (rev 01)
00:01.1 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 1 (rev 01)
00:02.0 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 2 (rev 01)
00:02.1 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 2 (rev 01)
00:02.2 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 2 (rev 01)
00:02.3 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 2 (rev 01)
00:03.0 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 3 (rev 01)
00:03.1 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 3 (rev 01)
00:03.2 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 3 (rev 01)
00:03.3 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 3 (rev 01)
00:04.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 0 (rev 01)
00:04.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 1 (rev 01)
00:04.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 2 (rev 01)
00:04.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 3 (rev 01)
00:04.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 4 (rev 01)
00:04.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 5 (rev 01)
00:04.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 6 (rev 01)
00:04.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 7 (rev 01)
00:05.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Map/VTd_Misc/System Management (rev 01)
00:05.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO Hot Plug (rev 01)
00:05.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO RAS/Control Status/Global Errors (rev 01)
00:05.4 PIC: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D I/O APIC (rev 01)
00:11.0 Unassigned class [ff00]: Intel Corporation C610/X99 series chipset SPSR (rev 05)
00:1a.0 USB controller: Intel Corporation C610/X99 series chipset USB Enhanced Host Controller #2 (rev 05)
00:1c.0 PCI bridge: Intel Corporation C610/X99 series chipset PCI Express Root Port #1 (rev d5)
00:1c.2 PCI bridge: Intel Corporation C610/X99 series chipset PCI Express Root Port #3 (rev d5)
00:1c.4 PCI bridge: Intel Corporation C610/X99 series chipset PCI Express Root Port #5 (rev d5)
00:1c.6 PCI bridge: Intel Corporation C610/X99 series chipset PCI Express Root Port #7 (rev d5)
00:1c.7 PCI bridge: Intel Corporation C610/X99 series chipset PCI Express Root Port #8 (rev d5)
00:1d.0 USB controller: Intel Corporation C610/X99 series chipset USB Enhanced Host Controller #1 (rev 05)
00:1f.0 ISA bridge: Intel Corporation C610/X99 series chipset LPC Controller (rev 05)
00:1f.3 SMBus: Intel Corporation C610/X99 series chipset SMBus Controller (rev 05)
01:00.0 System peripheral: Hewlett-Packard Company Integrated Lights-Out Standard Slave Instrumentation & System Support (rev 06)
01:00.1 VGA compatible controller: Matrox Electronics Systems Ltd. MGA G200EH (rev 01)
01:00.2 System peripheral: Hewlett-Packard Company Integrated Lights-Out Standard Management Processor Support and Messaging (rev 06)
01:00.4 USB controller: Hewlett-Packard Company Integrated Lights-Out Standard Virtual USB Controller (rev 03)
02:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5719 Gigabit Ethernet PCIe (rev 01)
02:00.1 Ethernet controller: Broadcom Corporation NetXtreme BCM5719 Gigabit Ethernet PCIe (rev 01)
02:00.2 Ethernet controller: Broadcom Corporation NetXtreme BCM5719 Gigabit Ethernet PCIe (rev 01)
02:00.3 Ethernet controller: Broadcom Corporation NetXtreme BCM5719 Gigabit Ethernet PCIe (rev 01)
03:00.0 RAID bus controller: Hewlett-Packard Company Smart Array Gen9 Controllers (rev 01)
04:00.0 Ethernet controller: Intel Corporation 82599ES 10-Gigabit SFI/SFP+ Network Connection (rev 01)
04:00.1 Ethernet controller: Intel Corporation 82599ES 10-Gigabit SFI/SFP+ Network Connection (rev 01)
08:00.0 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01)
-----
ff:16.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Global Broadcast (rev 01)
ff:17.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 1 - Channel 0 Thermal Control (rev 01)
ff:17.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 1 - Channel 1 Thermal Control (rev 01)
ff:17.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 1 - Channel 0 Error (rev 01)
ff:17.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 1 - Channel 1 Error (rev 01)
ff:17.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface (rev 01)
ff:17.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface (rev 01)
ff:17.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface (rev 01)
ff:17.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface (rev 01)
ff:1e.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
ff:1e.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
ff:1e.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
ff:1e.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
ff:1e.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
ff:1f.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
ff:1f.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)

10.查看是否是SSD硬盘:

# cat /sys/block/sda/queue/rotational
1
因为SSD是非转动盘,如果返回结果为0说明是SSD硬盘,如果返回结果为1,说明是转动盘HDD类的硬盘。
# lsblk -d -o name,rota
NAME ROTA
fd0     1
sda     1
sr0     1

11.使用工具查看是否是SSD:

yum -y install hdparm
yum -y install install smartmontools--查看磁盘的详细信息:
sudo hdparm -I /dev/sdb
sudo smartctl -a /dev/sda--查看是否是SSD磁盘:
# sudo hdparm -I /dev/sdb/dev/sdb:
SG_IO: bad/missing sense data, sb[]:  70 00 05 00 00 00 00 0a 00 00 00 00 20 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00ATA device, with non-removable media
Standards:
Likely used: 1
Configuration:
Logicalmaxcurrent
cylinders00
heads00
sectors/track00
--
Logical/Physical Sector size:           512 bytes
device size with M = 1024*1024:           0 MBytes
device size with M = 1000*1000:           0 MBytes
cache/buffer size  = unknown
Capabilities:
IORDY not likely
Cannot perform double-word IO
R/W multiple sector transfer: not supported
DMA: not supported
PIO: pio0 # sudo smartctl -x /dev/sdb
smartctl 6.5 2016-05-07 r4318 [x86_64-linux-3.10.0-327.el7.x86_64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org=== START OF INFORMATION SECTION ===
Vendor:               HP
Product:              LOGICAL VOLUME
Revision:             4.52
User Capacity:        2,400,348,626,944 bytes [2.40 TB]
Logical block size:   512 bytes
Physical block size:  4096 bytes
Rotation Rate:        Solid State Device
Logical Unit id:      0x600508b1001c14bfd2545ce4ee7b9d15
Serial number:        PVYKH0BRH96097
Device type:          disk
Local Time is:        Fri Sep 28 16:09:53 2018 CST
SMART support is:     Available - device has SMART capability.
SMART support is:     Enabled
Temperature Warning:  Disabled or Not Supported
Read Cache is:        Enabled
Writeback Cache is:   Disabled=== START OF READ SMART DATA SECTION ===
SMART Health Status: OK
Current Drive Temperature:     0 C
Drive Trip Temperature:        0 CError Counter logging not supportedDevice does not support Self Test logging
Device does not support Background scan results logging注释:可以看到Rotation Rate:        Solid State Device。smart工具集的信息比hdparm的要更细致,你也可以使用图形界面下的smartctl,
首先安装图形界面安装包yum -y install gsmartcontrol

12. 查看键盘和鼠标

cat /proc/bus/input/devices

13.查看磁盘信息:

# fdisk -l & df -h
Disk /dev/sda: 1000.2 GB, 1000171331584 bytes, 1953459632 sectors
Units = sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 262144 bytes / 262144 bytes
Disk label type: dos
Disk identifier: 0x0001c960Device Boot      Start         End      Blocks   Id  System
/dev/sda1            2048  1953458175   976728064   83  LinuxDisk /dev/sdb: 2400.3 GB, 2400348626944 bytes, 4688180912 sectors
Units = sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 4096 bytes
I/O size (minimum/optimal): 262144 bytes / 1310720 bytes
Disk label type: dos
Disk identifier: 0xcf27427cDevice Boot      Start         End      Blocks   Id  System
/dev/sdb1            2560  4294967294  2147482367+  83  Linux[1] 462208
Filesystem      Size  Used Avail Use% Mounted on
/dev/sda1       932G   14G  918G   2% /
devtmpfs         95G     0   95G   0% /dev
tmpfs            95G     0   95G   0% /dev/shm
tmpfs            95G  338M   95G   1% /run
tmpfs            95G     0   95G   0% /sys/fs/cgroup
/dev/sdb1       2.0T  646G  1.3T  34% /data
tmpfs            19G     0   19G   0% /run/user/1001
tmpfs            19G  4.0K   19G   1% /run/user/0
tmpfs            19G     0   19G   0% /run/user/1000

14.查看USB设备:

cat /proc/bus/usb/devices

15.查询所有硬件信息:

yum -y install lshw
yum -y install lshw-gui
适用于所有的linux,包括Redhat、SuSE、Debian等发行版。

16.查询系统版本:

#yum -y install redhat-lsb
lsb_release -a ,即可列出所有版本信息
# lsb_release -a
LSB Version::core-4.1-amd64:core-4.1-noarch:cxx-4.1-amd64:cxx-4.1-noarch:desktop-4.1-amd64:desktop-4.1-noarch:languages-4.1-amd64:languages-4.1-noarch:printing-4.1-amd64:printing-4.1-noarch
Distributor ID:CentOS
Description:CentOS Linux release 7.2.1511 (Core)
Release:7.2.1511
Codename:Core

Linux 服务器信息查看相关推荐

  1. Python之Django实例--sysinfo项目搭建(中文版 Linux 服务器信息查看应用)

    文章目录 1. 创建项目 1.1 创建项目 1.2 创建App 1.3 配置setting 1.4 生成迁移文件并设置管理员 1.5 测试是否配置成功 1.6 git 提交 1.6.1 设置忽略文件 ...

  2. linux服务器关机日期,linux服务器last查看关机记录

    1.查看重启记录 last reboot命令 [root@test ~]# last reboot reboot system boot 2.6.-.el6.x Mon May : - : (+:) ...

  3. Linux服务器性能查看分析调优

    一 linux服务器性能查看 1.1 cpu性能查看 1.查看物理cpu个数: cat /proc/cpuinfo |grep "physical id"|sort|uniq|wc ...

  4. Linux服务器性能查看分析

    一 linux服务器性能查看 1.1 cpu性能查看 1.查看物理cpu个数: cat /proc/cpuinfo |grep "physical id"|sort|uniq|wc ...

  5. redhat linux 硬件信息查看

    redhat linux 硬件信息查看 查看服务器型号序列号 dmidecode|grep "System Information" -A9 查看主板型号 dmidecode | ...

  6. Linux记载磁盘信息,分享一款高逼格的Linux磁盘信息查看工具

    原标题:分享一款高逼格的Linux磁盘信息查看工具 可以使用df命令来显示在Linux.macOS和类Unix系统中挂载的文件系统上有多少可用磁盘空间.还可以使用du命令来估计文件空间的使用情况.我们 ...

  7. linux服务器状态查看命令,Linux服务器操作系统查看命令

    Linux服务器操作系统的性能分析我们可以通过命令来查看详细信息.下面由学习啦小编为大家整理了Linux服务器操作系统查看命令,希望对大家有帮助! Linux服务器操作系统查看命令 一 .linux服 ...

  8. Linux服务器基本信息查看命令

    前言 Linux是一套免费使用和自由传播的类Unix操作系统,是一个基于POSIX和Unix的多用户.多任务.支持多线程和多CPU的操作系统.伴随着互联网的发展,Linux得到了来自全世界软件爱好者. ...

  9. linux服务器怎么查看cpu配置信息,linux服务器cpu信息查看详解

    在linux系统中,提供了/proc目录下文件,显示系统的软硬件信息.如果想了解系统中CPU的提供商和相关配置信息,则可以查/proc/cpuinfo.但是此文件输出项较多,不易理解.例如我们想获取, ...

最新文章

  1. mysql触发器和存储过程_MySql的存储过程和触发器
  2. 如何用 SpringBoot 实现并发登录人数控制(附代码)
  3. java事件监听器无效_Java的事件监听器学习心得
  4. waf可以检测哪个端口的流量_锐速云:CC防御过程中,WAF的主要特点有哪些?
  5. Android中ListView数据使用sAdapter.notifyDataSetChanged();方法不刷新的问题
  6. Canvas--文字渲染
  7. .htaccess防盗链方法(文件、图片)
  8. android勾选控件_【Android 开发】:UI控件之复选框控件 CheckBox 的使用方法
  9. sql中 replace函数
  10. 【FPGA基础】四位二进制--格雷码转换器(vivado)
  11. 小米盒子服务器无信号,小米小盒子连接HDMI无信号怎么办?
  12. c语言get获取数组参数,C语言访问数组元素
  13. phpcms v9 站内外搜索代码
  14. FindBugs的使用
  15. java-net-php-python-java宿舍管理系统计算机毕业设计程序
  16. Java导出Excel文档(poi),并上传到腾讯云对象存储服务器
  17. Win11重启后无法进入系统解决办法
  18. 软件测试之安装数据库
  19. 《趣学Python编程》——第1部分 学习编程 第1章 Python不是大蟒蛇 1.1 关于计算机语言...
  20. 企业邮箱价格多少钱?邮箱购买价格多少钱?

热门文章

  1. Excel 2010 VBA 入门 104 利用VBA生成图表
  2. 手机生成ODEX提升开机速度的原因
  3. 从点子到产品:产品经理的价值观与方法论
  4. 反欺诈概念库-虚假交易
  5. Hive四舍五入等用法
  6. 水果作物异常检测论文、代码和数据汇总
  7. javacv实现图片去水印
  8. Android 基础知识3:四大组件之 Broadcast(广播)
  9. 利用Java的BigDecimal计算高精度圆周率
  10. 余额宝安全吗?你们都存了多少?